1. Remove the FAUCET SPOUT (1) by unthreading
the LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET SPOUT
SCREW (4) at the back of the FAUCET. Pull
FAUCET SPOUT (1) up and off. Fig. 2.
2. Disconnect the BLACK POWER SUPPLY
CONNECTOR (1) and reconnect. Fig. 3.
3. While the SENSOR CONTROL LED (2) is blinking
slowly, place your hand 1 - 2 in. (25.4-50.8mm) in
front of the sensor. Fig. 4.
4. When the LED stops blinking and stays "ON", move
your hand to the desired position and hold in place
until the LED begins to blink again. Fig. 4a.
5. Once the SENSOR CONTROL LED (2) begins to
blink again, remove your hand from the detection
zone. When the flashing stops, the detection
distance is set.
6. Replace FAUCET SPOUT (1) and LEVER HANDLE
(3). Install LEVER HANDLE SCREW (2), FAUCET
SPOUT SCREW (4) and tighten. Fig. 2.
Note: The LEVER HANDLE (3) can be removed to
prevent users from adjusting the water temperature.
Replace the LEVER HANDLE (3) with PLUG
BUTTON (5) as shown. Fig. 2.
CHANGE SENSOR RANGE;
(Factory set at 6") Fig. 2, 3, 4, & 4a
B
1
4
3
5
2
REMOVE
REPLACE
Fig. 3
1
Fig. 4 Fig. 4a
UP TO 10"
(254mm)
BLINKING LED
2
BLINKING LED
2
1"-2"
(25.4mm-
50.8mm)
M965654 Rev. 2.2 (12/17)