TROUBLESHOOTING GUIDE
Does not
flush
Poor or
sluggish
flush
Toilet leaks
Toilet does
not shut off
Toilet bowl
rocks after
installation
a. Water supply valve closed.
b. Supply line blocked.
*c. Flush valve chain too loose or disconnected.
**c. Push button requires adjustment.
d. Sand or debris lodged in water control.
***e. Paddle not fully depressed
a. Bowl water level too low.
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe
and/or vent.
d. Supply pressure too low.
a. Poor supply line connection.
b. Poor bowl to tank/floor connection.
a. Flapper seal leaking or deformed.
b. Sand or debris lodged in water control.
*c. Flush valve chain too tight, holding flapper open.
a. Wax ring not fully compressed.
b. Floor not level.
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all gaskets
and washers. Reassemble.
*c. Readjust chain length as required. See Step 12.
**c. Install Push Button Rods for 2-7/8" (75mm) extended length. See Step 10.
*d. Shut off water supply. Remove cap and clean as per Fluidmaster
maintenance instructions at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
**d. Shut off water supply. Remove supply line, remove & clean inlet port filter.
***e. To ensure that the proper function is achieved, push the desired paddle full
stroke and quickly release.
a. Check that refill tube is connected to water control and
inserted into overflow tube without being kinked or damaged.
b. Open supply valve fully. Be sure that proper supply tube size is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
a. Review Steps 9a and 9b of installation procedure.
b. Review Steps 1 through 7 of installation procedure.
a. Clean debris from seal surface. Replace flapper seal as needed.
*b. Shut off water supply. Remove cap and clean as per Fluidmaster
maintenance instructions at:
www.americanstandard-us.com/enews/fluidmasterguide.pdf
**b. Shut off water supply. Remove supply line, remove & clean filter inlet port.
*c. Readjust chain length as needed. See Step 12.
a. Retighten bowl-to-floor knobs.
b. Use toilet shims and /or place a bead of caulk around the base of the toilet.
Problem Possible Cause Corrective Action