Instructions / Assembly

7301456-100 Rev. C
6
8
7
INSTALL TANK
a. Install large rubber gasket over threaded outlet on bottom of tank and
lower tank onto bowl so that tapered end of gasket fits evenly into bowl
water inlet opening, and tank mounting bolts go through mounting
holes. Secure with metal washer/nut combo.
b. With tank parallel to wall, alternately tighten nuts until tank is snugged
down evenly against bowl surface.
!
- 2 -
CAUTION:
DO NOT OVERTIGHTEN NUTS MORE
THAN REQUIRED FOR A SNUG FIT!
For Tanks/Bowls using Speed Connect System
(Tank mounting bolts pre-installed).
USE INCLUDED TOOL, NUT DRIVER, OR DEEP SOCKET RACHET.
*
9a
9b
Before continuing, determine the type of water supply connecation you have from
the chart below and use the appropriate assembly parts required to properly
reconnect the water supply. DO NOT use plumber's putty to seal these fittings.
CAUTION: DO NOT USE
CONE WASHER WITH
PLASTIC SUPPLY LINE.
These parts must be used as
illustrated to insure water-tight
connection. Use of existing
coupling nut may result in water
leakage. Water supply tube or pipe
must extend at least 1/2" inside
threaded shank of valve (does not
apply to flanged tubing).
Use existing
coupling nut
and washer.
Use existing spiral
cone washer.
Fluidmaster cone
washer may not
seal completely on
spiral type supply
line.
Captive cone
washers already
included. No
additional washers
needed.
CAUTION: Overtightening of
LOCK NUT or COUPLING NUT
could result in breakage and
potential flooding.
METAL / COPPER
FLARED TUBING
METAL FLANGED
TUBING
METAL SPIRAL
TUBING
VINYL / BRAIDED
CONNECTOR
LOCK NUTLOCK NUT LOCK NUT LOCK NUT
COUPLING
NUT
COUPLING
NUT
EXISTING
COUPLING
NUT
COUPLING
NUT
WATER
SHUT-OFF
WATER
SHUT-OFF
WATER
SHUT-OFF
WATER
SHUT-OFF
CONE
WASHER
EXISTING
CONE
WASHER
EXISTING
WASHER
With correct washers in
place (see Step 9a),
tighten COUPLING NUT
1/4 turn beyond hand tight.
DO NOT OVERTIGHTEN.
!
WARNING: Do not use plumber’s putty, pipe dope, or any other sealant on the water supply connection to this tank. If the connection
leaks after hand tightening, replace the supply line. If the connection continues to leak with the new supply line, replace the fill valve.
Warranty is void if any type of sealant is used on the water supply connection.
a. Position toilet squarely to wall and, with a rocking motion, press bowl
down fully on wax ring and flange.
Alternately tighten nuts until toilet is firmly seated on floor.
CAUTION: DO NOT OVERTIGHTEN
NUTS OR BASE MAY BE DAMAGED!
b. Install bolt covers:
1. Make sure that the bolt cover area on the toilet is clean and
dry (see figure). Use a dry piece of cloth or soap and water
if needed.
2. Take plastic bolt cover and peel the brown protective film off
on both ends. The adhesive part is now visible and ready to
be placed on the toilet (see figure).
3. Gently place the bolt cover on the toilet area (see picture) and if
everything is aligned, push bolt cover firmly so it remains in place.
4. If not aligned, you can still take it off and put it back so it is aligned.
5. Repeat Step 3 for second bolt cover which is to be placed on opposite side of the toilet.
6. After 24 hours, the bolt cover adhesive has completely set off and if needed, you can remove/replace
as needed. The dual lock technology is now in place.
c. Smooth off the bead of sealant around base. Remove excess sealant.
!
INSTALL TOILET
CLOSET BOLT
NUT
BOLT COVER
Peel both protective films off
and stick bolt cover to toilet.
Back Side
Front Side
BOLT COVER
BOLTS
CLOSET FLANGE
INSTALL TOILET SEAT: Install toilet seat in accordance with manufacturer's directions.
RUBBER
GASKET
TANK MTG.
BOLTS PRE-
INSTALLED
WASHER/
NUT
COMBO