Installation Guide

7302427-100 (3/19)
10 11
ADJUSTMENTS
a. Adjust water level. Water level should
be adjusted to level indicated on tank
by adjusting float cup.
See Step 11 for water level adjustment
method
b. If bowl fails to siphon, an adjustment
may be required with the lift chain.
Simply remove the bead chain from
the retainment clip and take up slack
on the chain, and reinsert on lift rod.
Make sure the chain is not too taught.
12
- 3 -
CARE AND CLEANING
When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents,
disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat. Some
bathroom chemicals and cosmetics may damage the seat's finish.
WARNING: Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the
tank. This damage can cause leakage and property damage.
American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing
chlorine (calcium hypochlorite).
!
VALVE
BODY
ADJUSTABLE
HEIGHT
WATER LEVEL
ADJUSTMENT
ROD
Turn on water supply.
Submerge the FLOAT CUP
under the water for 30 seconds.
Adjust the water to desired level
by turning WATER LEVEL
ADJUSTMENT ROD and
moving FLOAT CUP up or
down.
TANK
LEVER
FLUSH
VALVE
TOP
ARM
NIPPLE
Diagram 1
PARTS FOR WATER
CONNECTION
(SEE STEP 9)
CONE WASHER
FLAPPER
THREADED
SHANK
SHANK
WASHER
COUPLING NUT
(HAND TIGHT ONLY)
FILL
VALVE
FLOAT
CUP
CRITICAL LEVEL
MARK ("C.L.")
MUST BE
1" ABOVE
OVERFLOW PIPE
REFILL
TUBE
LOCK NUT
9a
9b
Before continuing, determine the type of water supply connecation you have from
the chart below and use the appropriate assembly parts required to properly
reconnect the water supply. DO NOT use plumber's putty to seal these fittings.
CAUTION: DO NOT USE
CONE WASHER WITH
PLASTIC SUPPLY LINE.
These parts must be used as
illustrated to insure water-tight
connection. Use of existing
coupling nut may result in water
leakage. Water supply tube or pipe
must extend at least 1/2" inside
threaded shank of valve (does not
apply to flanged tubing).
Use existing
coupling nut
and washer.
Use existing spiral
cone washer.
Fluidmaster cone
washer may not
seal completely on
spiral type supply
line.
Captive cone
washers already
included. No
additional washers
needed.
CAUTION: Overtightening of
LOCK NUT or COUPLING NUT
could result in breakage and
potential flooding.
METAL / COPPER
FLARED TUBING
METAL FLANGED
TUBING
METAL SPIRAL
TUBING
VINYL / BRAIDED
CONNECTOR
LOCK NUTLOCK NUT LOCK NUT LOCK NUT
COUPLING
NUT
COUPLING
NUT
EXISTING
COUPLING
NUT
COUPLING
NUT
WATER
SHUT-OFF
WATER
SHUT-OFF
WATER
SHUT-OFF
WATER
SHUT-OFF
CONE
WASHER
EXISTING
CONE
WASHER
EXISTING
WASHER
With correct washers in
place (see Step 9a),
tighten COUPLING NUT
1/4 turn beyond hand tight.
DO NOT OVERTIGHTEN.
!
WARNING: Do not use plumber’s putty, pipe dope, or any other sealant on the water supply connection to this tank. If the connection
leaks after hand tightening, replace the supply line. If the connection continues to leak with the new supply line, replace the fill valve.
Warranty is void if any type of sealant is used on the water supply connection.