Installation Guide

COLD
OFF
ON
4
TEST INSTALLED FAUCET
AND CHECK FOR LEAKS
1
2
3
COLD
HOT
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
6
CARE INSTRUCTIONS:
5
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M965228 REV. 1.5 (2/15)
HOT
2
2.5mm HEX KEY
5
6
7
1
4
SERVICE
To remove or replace cartidge: Fig. A.
Turn valve to OFF position.
Remove HANDLE SCREW (2).
Pull off HANDLE (3) and CAP (4).
Unthread CARTRIDGE NUT (5) and remove.
Pull out CARTEIDGE (6).
Inspect CARTRIDGE (6) and O-RING (7) for
debris and clean if necessary.
Clean MANIFOLD (1) and rinse clean.
Reinstall CARTRIDGE (6) and O-RING (7) onto
MANIFLOD (1).
Reinstall CARTRIDGE NUT (5), CAP (4) and
HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from
OFF to ON and HOT to COLD position. Do not
force - handles turn only 90˚.
Turn off hot and cold water
supplies before beginning.
CAUTION
3