Installation Guide

- 3 -
6
7
CARE INSTRUCTIONS:
TEST INSTALLED FITTING
5
M965962 (5/18)
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
SERVICE
CAUTION
Turn off hot and cold water
supplies before begining.
TO REMOVE
HANDLE
90˚
3
2
5
4
1
3
2
1
1
AERATOR
SET
SCREW
To change direction of handle rotation, proceed as follows:
— Turn valve to OFF position.
Thread counter-clock wise HANDLE BASE (1) to remove
HANDLE ASSEMBLY (2) from VALVE HOUSING (3).
Thread counter-clock wise VALVE HOUSING (3) to remove.
Use a at blade screw driver to remove SPRING CLIP (4).
Lift STOP WASHER (5), turn 90˚ and replace.
Replace SPRING CLIP (4).
Reinstall all parts and HANDLE ASSEMBLY (2).
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (2).
Operate both HANDLES (1) to ush water lines thoroughly.
• Replace AERATOR (3).
• Check all drain connections for leaks.