MAKE WATER SUPPLY
CONNECTIONS; Fig. 4
1. Turn off hot and cold water supplies before beginning.
2. Place each SCREEN FILTER (3) on each wall supply
outlet. Be sure that SCREEN FILTER (3) is inserted
in the correct direction. (See Illustration)
3. Connect HOT FLEXIBLE SUPPLY (marked with red
stripe) (1) to hot water control stop (4). Connect COLD
FLEXIBLE SUPPLY (marked with blue stripe) (2) to cold
water control stop (5). Use adjustable wrench to tighten
connections. Do not over tighten.
4. Faucet supplies are 24" long from faucet base.
Note; If additional supply length is required, installer
must purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long, loop
as illustrated to avoid kinking.
Fig. 4
Fig. 5
DETECTION
ZONE
PROTECTIVE FILM
IMPORTANT: Do not
use sealent on threads
1
2
3
COLD
HOT
(3) SCREEN
FILTER
BULGE
SIDE DOWN
Fig. 1
Installation Instructions
(In Toronto Area only: 1-905-3061093)
SELECTRONIC™
Thermostatic Mixing Valve
Certified to comply with ASME A112.18.1M
© 2005 American Standard
M968808
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.
customer's e-mail us at: faucetsupport@amstd.com
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-80 0-387-0369)
NOTE TO INSTALLER: Please give this manual to the customer after installation.
(In Toronto Area only: 1-905-3061093)
605XTMV
Specifications
Installation
Adjust Temperature
Service
Replacement Parts
1
2
3
3
4
No. M968808
HOT
SUPPLY
COLD
SUPPLY
TEE
FITTING
Optional Mixing Valve
(Sold Separately)
TEMPERED
WATER SUPPLY
COLD
WATER
5
4
E
INSTALL OPTIONAL MIXING
VALVE; Fig. 5
Note: An optional Thermostatic Mixing Valve (sold
separately) may be installed on faucets 775X.1XX &
775X.2XX in addition to Above Deck Mixing valve.
See setup diagram Fig. 5.
Te etting is not supplied with Faucet or Thermostatic
Mixing valve and must be purchased separately. If faucet
inlet hoses will not reach water supplies, longer hoses
must be purchased separately.
For complete detailed installation and operating
instructions, see installations instructions (No. M968808)
supplied with Thermostatic Mixing Valve.
MAINTENANCE
A
HAND WASH SENSOR
OPERATION; Fig. 1
REMOVE PROTECTIVE FILM FROM SENSOR EYE
WHEN INSTALLATION IS COMPLETE.
When the Sensor detects a user, the water immediately
starts to ow. Water ow will stop 1.5 seconds after user is
out of sensor range. This Comfort delay allows the user to
comfortably move their hands without the water turning off.
As a precaution, a Safety Timer will turn off the water, after
the sensor has been blocked for 59 seconds. The water will
stay off until the blockage is removed from the detection
zone.
The Comfort and Safety time settings can be adjusted using
the Optional Remote Control (605XRCT).