VANITY INSTALLATION - FLOOR STANDING VANITY (CONTINUED)
Provide suitable reinforcement for anchoring the vanity to the wall. Centerline of reinforcement should be 27-7/8" up from
the floor (see Figure 2.2).
Rough in supply lines and waste per rough-in dimensions (see Figure 2.3).
Decorative molding may need to be notched to seat the vanity flush against the wall.
Move the Tropic 20" Vanity into place and level with the adjustable levellers on the bottom of the feet. The levellers can be adjusted
outward up to 1" but it is recommended not to exceed 1/2" if possible.
Drill at least two 3/8" O.D. anchoring holes through the centerline of the Top Rear Stringer of the vanity.
Anchor the vanity securely to the wall through the Top Rear Stringer of the vanity (see Figure 2.3).
Continue with installation appropriate for sink and faucet options chosen.
FIGURE 2.3
2
- 5 -
FIGURE 2.2
C/L OF 2 X 6
REINFORCEMENT
FINISHED
FLOOR
27-7/8"
(708mm)
ANCHOR VANITY
TO WALL USING
TOP REAR
STRINGER
ADJUSTABLE
LEVELLERS
(UNDER
EACH LEG)
ADJUSTABLE
LEVELLERS
(UNDER EACH LEG)
1-1/4"
O.D.
WASTE
23-3/8"
(595mm)
20"
(508mm)
16"
(406mm)
18"
(457mm)
18"
(460mm)
TROPIC PETITE
PEDESTAL SINK
FINISHED FLOOR
FINISHED FLOOR
FINISHED
WALL
SUPPLIES
AS REQUIRED
11"
(280mm)
8"
(203mm)
34-3/8"
(874mm)
36"
(920mm)
SECURE VANITY
TO WALL USING
TOP REAR STRINGER
J-RAIL REQUIRED FOR
WALL HUNG VERSION
ONLY (PLEASE DISCARD
FOR FREESTAND
VERSION AS SHOWN)
36"
(917mm)
2"
(51mm)
27-7/8"
(708mm)
6-1/2"