Product specifications

ACONT900AC43UA
Pub. No. 11-HD04D1-2
13 69-2080—05
Furnace Filter 2
Change Reminder
0501 E, 0 E, 0 - 14 E - Auto-Discover
0 - Disabled (reminder off)
1 - 10 run time days
2 - 30 run time days
3 - 60 run time days
4 - 90 run time days
5 - 120 run time days
6 - 180 run time days
7 - 270 run time days
8 - 365 run time days
9 - 30 continuous days
10 - 60 continuous days
11 - 90 continuous days
12 - 120 continuous days
13 - 180 continuous days
14 - 365 continuous days
When set to Auto-Discover
(and the discovered value is
not 0=disabled), the
Comfort Control will display
the filter timer value it
receives from the
AccuLink
TM
communicating
filtering device on the More
screen.
To reset the filter timer of
the AccuLink
TM
communicating filtering
device, simply press the
More key to access the filter
timer value and then press
the Reset key. If no
AccuLink
TM
communicating
filtering device has been
discovered, the auto-
discovered value will default
to 0.
When not set to Auto-
Discover (and not set to
0=disabled), the Comfort
Control will display its
internal filter timer on the
More screen.
To reset the Comfort
Control's internal timer,
simply press the More key
to access the filter timer
value and then press the
Reset key.
Humidifier Pad
Replacement
Reminder
0510 E, 0 E, 0 - 3 E - Auto-Discover
0 - Disabled
1 - 90 continuous days
(30 run time days)
2 - 180 continuous days
(60 run time days)
3 - 365 continuous days
(90 run time days)
When controlling humidifier
settings, use run time days.
Otherwise, use calendar
days.
Adaptive Intelligent
Recovery
0530 1 0, 1 0 - Conventional recovery
is activated
1 - Adaptive Intelligent
Recovery control is
activated
Adaptive Recovery starts
recovery early to reach
setpoint by start of program
period.
Number of Periods 0540 4 2, 4 2 - Two Periods available
(Wake, Sleep)
4 - Four Periods available
(Wake, Leave, Return,
Sleep)
Selection applies to all days
of the week.
Not shown if
nonprogrammable is
selected.
Heat Temperature
Range Stop
0600 90 50 - 90 Highest heating setpoint.
Temperature range (1°F
increments) of heating
setpoint.
Shown in 1/2°C
Cool Temperature
Range Stop
0610 60 60 - 99 Lowest cooling setpoint.
Temperature range (1°F
increments) of cooling
setpoint.
Shown in 1/2°C
Minimum
Noncompressor On
Time
0620 3 0 - 15 Minimum number of
minutes non-compressor
(heat) equipment is on.
Table 4. Installer Setup Menu
Selection
Installer Setup
Number (ISU)
Factory
Setting
Choices
CommentsOption Description