Remove the jamb from the threshold. At each marked location, drill for installation of the
jamb. Use Table 3 to determine hole size and installation method for the u-channel
21
Align the Threshold U-Channel [4]
along the centerline marked on the
threshold.
Mark the hole locations on the wall.
20
Table 3 - Mounting Hole Drilling Requirements
Wall Material
Fiberglass or Acrylic Fiberglass or Acrylic Tile/Other
Reinforced Walls YES NO -
Drill Diameter 1/8" 1/8" 3/16"
Insert Required NO No Yes, Blue Insert
CL
22
Insert a small amount of silicone into each
drilled hole.
If applicable, insert a Blue Wall Plug [15]
into the hole. Carefully cut the head flush
with the wall using a razor blade.
Position the u-channel and secure with #8
Flat Head Screws [14].
Use caution so as to not strip the in-
serts or fiberglass wall material!
Wall hidden
for clarity