Installation & Assembly

7301450-100 Rev. 2 (3/19)
Does not flush
Poor or sluggish flush
Toilet leaks
Toilet does not shut off
a. Water supply valve closed.
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
a. Bowl water level too low.
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe and/or vent.
d. Supply pressure too low.
e. Flush valve chain too tight, holding flush valve open.
a. Poor supply line connection.
b. Poor bowl to tank/floor connection.
a. Flush valve seal leaking or deformed.
b. Sand or debris lodged in water control.
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all
gaskets and washers. Reassemble. Also, see Fluidmaster
maintenance. (see Step 12)
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Step 12.
a. Check that refill tube is connected to water control and
inserted into tank overflow without being kinked or damaged.
b. Open supply valve fully. Be sure that proper supply tube size
is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
e. Readjust chain length as needed. Review Step 9A.
a. Review Step 8a and 8b of installation procedure.
b. Review Step 4 through 6 of installation procedure.
a. Clean debris from seal surface. Replace flush valve seal as
needed.
b. Shut off water supply. Remove cap and clean as per Step 12.
TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
- 4 -
12
Make sure water supply is
off. Remove valve TOP by
lifting arm and rotating top
and arm 1/8 turn
counterclockwise, pressing
down slightly on cap.
IMPORTANT: Always
clear sand and rust from
system.
While holding a
container over the
uncapped VALVE to
prevent splashing, turn
water supply on and off
a few times. Leave
water supply off.
Replace TOP by engaging
lugs and rotating 1/8 turn
clockwise. MAKE
CERTAIN TIP IS TURNED
TO THE LOCKED
POSITION. VALVE MAY
NOT TURN ON IF TOP IS
NOT FULLY TURNED TO
THE LOCKED POSITION.
For troubleshooting information please contact:
TROUBLESHOOTING
IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK
SLOWLY, repeat Step 12.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS
OF NON-USE,
it is a signal you are wasting water because:
The end of the refill tube is inserted into overflow pipe,
below water level in tank. Attach refill tube to overflow
pipe using "S" clip provided.
The flush valve is leaking because it's worn, dirty or
misaligned with tank ball or flapper (replace with a
new flapper).
IF FILL VALVE WON'T TURN ON OR SHUT OFF or
REFILL OF TANK WATER IS SLOW after valve has been
in use for some time, Fluidmaster Model 242
Replacement Seal may be needed.
Go to our website at www.fluidmaster.com for more
solutions to toilet problems.
© 2001 Fluidmaster, Inc.
® Registered trademark of Fluidmaster, Inc.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products.
Fluidmaster shall not be responsible or liable for any damages caused by products used
with Fluidmaster valves that were not manufactured by Fluidmaster, Inc.
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675
(949) 728-2000 (800) 631-2011
www.fluidmaster.com
LIFT ARM
FIRST
In the United States:
American Standard Brands
1 Centennial Ave
Piscataway, New Jersey 08854
Attention: Director of Customer Care
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 442-1902
www.americanstandard.com
In Canada:
AS Canada, ULC
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (800) 387-0369
www.americanstandard.ca
In Mexico:
American Standard B&K Mexico
S. de R.L. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Toll Free: 01-800-839-1200
www.americanstandard.com.mx