Installation Notes

Princeton™ Bath
w/Integral Overflow
Installation Instructions
Introduction:
1527mm
(60-1/8)
864mm(34)
TUB WIDTH
LEVELING STRINGER
51 x 102mm (2 X 4)
FRAMING INSTRUCTIONS
Note recess is
1527 X 914mm (
60-1/8 x 36). Cut a
229 x 305mm (
9 x 12) hole in sub floor
for drain, centered
464mm (
18-1/4) as shown. Locate studs as required, then ensure
rough opening dimensions are proper and supports are plumb and square.
*Install stringer as shown, (
346mm (
13-5/8) for through the floor drain;
435mm (
17-1/8)
for above the floor rough)
Thank you for selecting American-Standard...products which
have been the benchmarks of fine quality for over 100 years. To help insure
that the installation process will proceed smoothly, please read these
instructions carefully before you begin. Also carefully unpack and examine your
new plumbing fixture.
2394.202.ICH
2396.202.ICH
2395.202.ICH
2397.202.ICH
2394.202.IPB
2396.202.IPB
2395.202.IPB
2397.202.IPB
Observe Local Plumbing and Building Codes
5
1
791175-100 Rev. F
229 x 305mm
(9 X 12) FLOOR
CUTOUT FOR DRAIN
The Drain Assembly is enclosed with tub models
listed above-locate and retain for tub installation
before discarding tub carton
IMPORTANT
1524mm
(60)
864mm
(34)
FINISHED
WALL
19mm
(3/4)
FINISHED
WALL
FULL LENGTH SUPPORT STRINGER
OUTLINE OF
SKID PATTERN
197mm
(7-3/4)
9 X 12
HOLE IN SUB-FLOOR
464mm
(18-1/4)
149mm
(5-7/8)
89mm
(3-1/2)
ROUGHING-IN
© American Standard Inc. 2001
FOR AFTER-SALES SERVICE CALL 1 (800) 223-0068 WEEKDAYS.
LEFT HAND TUB ILLUSTRATED
RIGHT TUB IS REVERSED
356mm
(14)
PROVIDE FULL
LENGTH SUPPORT
STRINGER
AT THIS POINT
346mm
(13-5/8)
60mm
(2-3/8)
1-1/2 N.P.T.
THREADS
1-1/2 TUBING
THREAD INSIDE
ROUGH
FLOOR
445mm
(17-1/2)
PROVIDE FULL
LENGTH SUPPORT
STRINGER
AT THIS POINT
435mm
(17-1/8)
ROUGH
FLOOR
DRAIN SHOE
BELOW FLOOR ROUGH
2394.202 ICH
2395.202 ICH
ABOVE FLOOR ROUGH
2396.202 ICH
2397.202 ICH
*346mm
(13-5/8)
464mm
(18-1/4)
914mm