System information

20 Numbers in [brackets] are for 50 Hz international systems. EAC-SF-13
Service Facts
instructions). The top three Red LEDs should be on for this
test. The three Red LEDs being on indicates that the Air
Cleaner Power level setting is set at the Maximum / 9.6 KV
position. If all three are NOT on, press the POWER
button
three times and then press the RESET button until you get
all three Red LEDs on. Now press and hold both the POWER
button and the RESET button for 5 [6] seconds then
release these buttons to exit the SET-UP mode. The first
Green LED will be on and it will start flashing after the first
10 [12] minutes of indoor fan operation. The Air Cleaner has
to have a call for operation for the first Green LED to flash on
and off. (A call for indoor blower or heat is a call for operation.)
6. When the first Green LED is flashing on and off, take the
screwdriver by the plastic handle and move the blade end
of the screwdriver near the Power Door High Voltage termi-
nal. When the end of the paper touches the High Voltage
terminal the High Voltage should arc across the paper.
When the arc occurs, the High Voltage Supply will shut down
and stay off for one minute.
7. Turn off the Air Cleaner by pushing the POWER
button.
8. Remove the wire and tape used to defeat the interlock switch.
9. If the arc occurred when the end of the paper was near or
touching the Power Door High Voltage terminal during this
test, the Power Door assembly is OK. If no arc occurred
replace Power Door with a new Power Door.
h
* May be "A" or "T"
PRESSURE DROP
400 CFM 600 CFM 800 CFM 1000 CFM 1200 CFM 1400 CFM 1600 CFM 1800 CFM 2000 CFM
*FD145CLFR000D
0.06
0.10
0.16
0.23
0.30
*FD175CLFR000D
0.05
0.08
0.12
0.17
0.22
0.28
0.34
*FD210CLFR000D
0.04
0.06
0.09
0.12
0.15
0.20
0.24
0.29
0.34
*FD245CLFR000D
0.03
0.04
0.06
0.09
0.12
0.15
0.19
0.22
0.26
*FD14DCLFR000D
0.09
0.16
0.24
0.34
0.46
*FD17DCLFR000D
0.07
0.11
0.18
0.25
0.33
0.42
*FD21DCLFR000D
0.05
0.09
0.13
0.18
0.23
0.29
0.37
*FD24DCLFR000D
0.04
0.07
0.11
0.14
0.19
0.24
0.30
0.36
0.43
*FD175CLAH000D
0.07
0.11
0.18
0.25
0.33
*FD215CLAH000D
TFD215CLAH005D
0.04 0.08 0.12 0.17 0.24
*FD235CLAH000D
TFD235CLAH005D
0.06 0.09 0.13 0.18 0.23 0.29 0.35
*FD260CLAH000D
TFD260CLAH005D
0.04 0.07 0.10 0.14 0.18 0.23 0.28 0.34 0.39
PRESSURE DROP AT SPECIFIC AIRFLOW PER MODEL