Flushometer Toilet Specification Sheet

M58
© 2008 AS America Inc.
NOTES:
PRODUCT 3451.160 AND 3453.160 SHOWN, 3452.160 AND 3455.160
SAME AS EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING.
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM
BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST
VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING.
THIS TOILET DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION
OF 254MM (10") AND A MAXIMUM DIMENSION OF 305MM (12") FROM
FINISHED WALL TO C/L OF OUTLET.
FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE
ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR
12" (305MM) ROUGH-IN: SWEAT EXTENSION NIPPLE IS REQUIRED.
REFER TO VALVE MANUFACTURER AND LOCAL CODES.
IMPORTANT: Dimensions of xtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.
238mm
(9-3/8)
419mm
(16-1/2)
438mm
(17-1/4)
470mm
(18-1/2)
356mm
(14)
338mm
(13-5/16)
150mm
(5-7/8)
254mm
(10)
13mm
(1/2)
76mm
(3)
718mm
(28-1/4)
C/L OF SEAT POST HOLES
140mm (5-1/2) CENTERS
FINISHED WALL
FINISHED
FLOOR
C/L OF OUTLET
MADERA™ 16-1/2" HEIGHT
1.6 GPF FLUSHOMETER TOILET
711mm
(28)
1 - 1/2
SPUD
121mm
(4-3/4)
238mm
(9-3/8)
419mm
(16-1/2)
470mm
(18-1/2)
356mm
(14)
338mm
(13-5/16)
150mm
(5-7/8)
254mm
(10)
13mm
(1/2)
25mm
(1)
102mm
(4)
718mm
(28-1/4)
C/L OF SEAT POST HOLES
140mm (5-1/2) CENTERS
FINISHED WALL
FINISHED
FLOOR
C/L OF OUTLET
1" N.P.T. OR 1" C.W.T. SUPPLY
TO FLUSH VALVE
3461.160/3462.160/3465.160/3466.160
3463.160/3464.160
Revised 12/08