Operating instructions

32-5027-16 3
User’s Information
NOTE THE LOCATION OF THE MANUAL MAIN GAS SHUTOFF VALVE FOR YOUR FURNACE.
Have your installer or servicer show you the location if you have any questions.
HORIZONTAL FURNACE Manual Main Gas Shut-off Valve May Be Located on the Top or Bottom Side
8. When thermostat is satisfied, main burners will
extinguish.
9. If main burners fail to ignite, lower thermostat setting
or disconnect electrical supply, wait 5 minutes, raise
thermostat setting above indicated temperature.
10. If furnace will not light, turn “OFF” all gas and elec-
tricity to unit and call servicer or gas supplier.
For complete shutdown.
Turn gas cock knob on main gas valve to “OFF” position.
Disconnect electrical supply to unit.
CAUTION
!
If this is done during the cold weather months, provisions
must be taken to prevent freeze-up of all water pipes and
water receptacles.
Whenever your house is to be vacant, arrange to have
someone inspect your house for proper temperature. If your
furnace should fail to operate, damage could result, such as
frozen water pipes.
Flame Roll-out Device.
All models are equipped with a fusible link located near the
burners. In case of flame roll-out, the link will open (melt)
and cause the circuit to open which shuts off all flow of gas.
UPFLOW FURNACE Manual Main Gas Shut-off Valve May Be Located on the Left or Right Side
TOP VIEW OF RIGHT SIDE PIPING