Installation Guide

- 5 -
M965907 Rev. 1.2 (8/19)
4
n Valve comes with Flush Plug that allows hot and cold supply lines to be ushed independently (without cross ow).
n Flush plug is shipped in Orientation A.
ORIENTATION A directs cold water through the shower port and hot water through the tub port.
n Flush plug can be reversed to Orientation B.
ORIENTATION B directs cold water through the tub port and hot water through the shower port.
n For shower only installation ush cold supply line rst in Orientation A. Then reverse to Orientation B and ush
hot supply line. Alternatively, the ush plug can be removed entirely to ush water through the valve body.
n To switch between orientations follow these steps:
Unthread BONNET NUT (1).
Rotate FLUSH PLUG (2) 90 degrees to desired orientation.
Rethread BONNET NUT (1).
n Upon completion of ushing both hot and cold supply lines unthread BONNET NUT (1), remove FLUSH PLUG (2),
and rethread BONNET NUT (1).
2
1
2 2
ORIENTATION BORIENTATION A (as shipped)
SHOWER
TUB
COLDHOT
SHOWER
TUB
COLDHOT
TEST PROCEDURES FOR FLUSH PLUG