INSTALL TRIM
1
7
5
11
3
2
4
10
9
8
6
1
3
Remove HOT LIMIT STOP (1) and CARTRIDGE (2).
Clean inlets and MANIFOLD (4).
Reassemble CARTRIDGE (3), alternately tightening SCREWS (2).
If faucet drips, operate CARTRIDGE PIVOT (A) handle several
times from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (3) inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply, then:
SERVICE
4
3
2
1
A
2
"B""A"
By restricting handle rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To
set the maximum hot water temperature of your faucet,
all you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
Remove HANDLE, CAP and HOT LIMIT STOP.
Follow "A" or "B" to adjust maximum discharge
temperature.
ADJUST HOT LIMIT STOP
ADJUSTMENT WHEN WATER IS TOO HOT
PRY UPWARD TO UNLOCK AND
ROTATE COUNTER-
CLOCKWISE ONE CLICK.
ADJUSTMENT WHEN WATER IS TOO COLD
PRY UPWARD TO UNLOCK AND
ROTATE CLOCKWISE ONE CLICK..
M968396 Rev. 1.2
4
Remove PLASTER GUARD (1).
Push CAP (2) on valve, place ESCUTCHEON (3) and attach with SCREWS (4).
Install HANDLE (5) by pushing it onto CARTRIDGE STEM (6) and tightening SET SCREW (7) from below.
Install SHOWER ARM (8) with FLANGE (9) and SHOWER HEAD (10).
Check proper operation of HANDLE (5) and DIVERTER SPOUT (11).
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.