Dimensions Guide

U.S. Patent No. D403,750
Patente estadounidense D403,750
Brevet U.S.A. no. D403,750
FINISHED WALL
PARED TERMINADA
MUR FINI
4"
4" (102 MM)
102 mm (4 po.)
TOP OF TUB RIM
BORDE SUPERIOR DE LA BAÑERA
HAUT DE REBORD DE BAIGNOIRE
BOTTOM OF TUB
FONDO DE LA BAÑERA
FOND DE BAIGNOIRE
74" FOR HEAD CLEARANCE
74" (188 CM) DE ALTURA
188 cm (74 po.) POUR DÉGAGER LA TÊTE
4" REF.
4" (102 MM) REF.
RÉF. 102 mm (4 po.)
1-5/8" TO 3-1/4"
1-5/8" A 3-1/4" (41 MM A 83 MM)
41 mm (1-5/8 po.) À 83 mm (3-1/4 po.)
18" OPTIONAL
18" (45,7 CM) OPTATIVO
OPTION 45,7 cm (18 po.)
*5-1/8" REF.
5-1/8" (130 MM) REF.
RÉF. 130 mm (5-1/8 po.)
*FOR COPPER SWEAT
OR SLIP-ON ONLY
1/2" NPT
1/2" (12,7 MM) NPT
12,7 mm (1/2 po.) NPT
1/2" COPPER
OR1/2" NPT''
1/2" (12,7 MM) COBRE
O 1/2" (12,7 MM) NPT''
CUIVRE 12,7 mm (1/2 po.)
OU NPT 12,7 mm (1/2 po.)
6"
6" (152 MM)
152 mm (6po.)
1" MIN.
1" (25 MM) MÍNIMO
MIN. 25 mm (1 po.)
5-1/2" REF.
5-1/2" (140 MM) REF.
RÉF. 140 mm (5-1/2 po.)
"SEE ILLUSTRATION "
VEA LA FIGURA INFERIOR
VOIR INSTALLATION CI-DESSOUS
Gracias por seleccionar los productos American Standard, sinónimo de la mejor
calidad durante más de 100 años. Por favor lea estas instrucciones detenidamente antes de
comenzar para que lleve a cabo la instalación sin contratiempos.
Nous vous remercions d’avoir choisi American Standard… synonyme de qualité supérieure
depuis plus de 100 ans. Pour vous assurer que l’installation se déroulera sans difficulté,
veuillez lire attentivement ces instructions avant de commencer.
Thank you for selecting American-Standard...the benchmark of fine
quality for over 100 years. To ensure that your installation proceeds
smoothly--please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1
Cumplimiento certificado de los requisitos
de la norma ANSI A112.18.1
Certifié conforme à ANSI A112.18.1
ROUGHING-IN DIMENSIONS
Instrucciones de instalación
Mode d’installation
Installation Instructions
To assure proper positioning in relation to wall,
note roughing-in dimensions.
Tome nota de las dimensiones de desbastado para
asegurar la posición correcta respecto de la pared.
Pour garantir un bon positionnement par rapport au
mur, tenir compte des dimensions de préparation.
M968763 Rev. 1.2
INSTALL TRIM
1
5
4
6
2
1
10
3
8
9
11
7
When finished tiling the wall, remove PLASTER GUARD (4). Push on CAP (1).
Mount ESCUTCHEON (2) and DIAL PLATE (3) with SCREWS (8).
Install HANDLE (9) by pushing it onto CARTRIDGE STEM (10) and tightening
SET SCREW (11) from below.
Remove cap from tub supply and plug from shower pipe.
Install SHOWER ARM with FLANGE (5) and SHOWER HEAD (6).
Install DIVERTER SPOUT (7).
For sweat inlets; 1/2" copper slip on spout.
For threaded inlets; 1/2" female NPT spout.
DIMENSIONES DE DESBASTADO
DIMENSIONS DE PRÉPARATION
COLONY SOFT
T675.508
T675.507
T675.502
T675.501
T675.500
T675.502
T675.501
T675.500
BATH/SHOWER TRIM KIT
JUEGO DECORATIVO PARA BANERA Y DUCHA
ENSEMBLE DE GARNITURES
DE BAIGNOIRE ET DOUCHE
0
1
2
3
4
5
6
T675.507
T675.508
With
FloWise™
SHOWER HEAD
FloWise™
CABEZA DE DUCHA
FloWise™
TÊTE DE DOUCHE
OPTIONAL TO FINISHED
FLOOR USUALLYBETWEEN 65'' AND 78''
HABITUELLEMENT ENTRE
165 cm (65 po.)
ET 198 cm (78 po.)
ENTRE OPTION ET PLANCHER FINI
OPTATIVO AL PISO TERMINADO,
POR LO GENERAL ENTRE
65" Y 78" (165 A 198 CM)
'
ASSISTANCE TÉLÉPHONIQUENUMBERO DE EMERGENCIAHOTLINE FOR HELP
For toll-free information and answers to your questions, call:
Para información y respuestas a sus preguntas, llame sin costo al:
Pour information et réponses à vos questions, composer sans frais:
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
1 800 442-1902
Weekdays Días laborales de las Sur semaine:
8:00 to 6:00 p.m. EST
CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays Días laborales de las Sur semaine:
8:00 to 7:00 p.m. EST

Summary of content (2 pages)