Service manual

Figure 1
Figure 2
Figure 3
Clearance/Flooring- If the water heater is installed directly on carpeting, it must be installed on a metal or wood panel which extends beyond
the full width and depth of the water heater by at least 3 inches in any direction. If the water heater is installed in an alcove, the entire floor must
be covered by the panel. A minimum of 24 inches front clearance shall be provided for inspection and servicing.
This water heater may be installed in an alcove on combustible flooring with clearances from combustible materials
as shown in Figures 1 and 2.
REMEMBER: Flammable vapors may be drawn to this water heater from
other areas of the structure by air currents.
NOTE: HEATER SHALL BE LOCATED OR PROTECTED SO IT IS NOT
SUBJECT TO PHYSICAL DAMAGE BY MOVING VEHICLES OR AREA
FLOODING.
Typical Installation in Residential Garages (Illustration copyright by the American
Gas Association. Used by permission of the copyright holder.)
The National Fuel Gas Code (ANSI Z223.1 /NFPA 54) expressly prohibits the following:
a) Installation of a water heater in a bathroom, bedroom, or any occupied room normally kept closed.
b) Installation of a water heater in a garage, unless the unit is installed so that the burner and ignition devices are at least eighteen ( 18) inches above
floor level and protected to avoid damage by moving vehicle. See Figure 3.
CAUTION
CLEARANCES FROM COMBUSTIBLE
CONSTRUCTION
ULN 75-76-AS, 75-76 AS-R-6,
75-76-AS-R-12
RU 75-76-AS-6, 75-76-AS-12
ULN 100-76-AS-R6, 100-76-AS-R-12
RU 100-76-AS-6, 100-76-AS-R-12
ULN 100-83-AS, 100-83-AS-R-6,
100-83-AS-R-12
RU 100-83-AS-6, 100-83-AS-12
18” 2” 6” 6”
A B C D
FRONT OPEN
CERTIFIED FOR INSTALLATION ON COMBUSTIBLE FLOOR
CERTIFIED FOR ALCOVE INSTALLATION
B
BB
D
C
D
AA
Vehicle Stop
Garage
18”
43
GENERAL
INSPECT SHIPMENT: Inspect water heater for possible damage. If damaged, notify carrier immediately. Check markings on rating plate to make
certain it corresponds with your application.
Read these instructions thoroughly before proceeding with the installation of this new gas-fired water heater. If there is any difficulty understanding
all or any part of these instructions, it is recommended that a qualified service person perform the installation.
NOTICE: The manufacturer's warranty does not cover damage or injury cause by the use of any energy-saving devices (other than those authorized
by the manufacturer) in conjunction with this water heater. The use of unauthorized energy-saving devices may decrease the life of the water heater
and endanger life and/or property. The manufacturer will not be held liable for loss or injury resulting from the use of any unauthorized device in
conjunction with this water heater.
This water heater has been equipped for use with one type of gas only. Compare the information provided on the rating plate affixed to the front
of the water heater, making sure that the gas stated on the rating plate is the same as the gas to be used. DO NOT ATTEMPT TO USE THIS
WATER HEATER WITH ANY GAS OTHER THAN THE TYPE LISTED ON THE RATING PLATE. Do not attempt to convert this water heater
for use with a gas other than the type for which it is equipped. Failure to use the proper gas can create an unsafe condition resulting in property
damage, bodily injury or death. Consult local gas supplier or gas company if there are any questions.
For installations in high altitude regions, this water heater must be ordered from the supplier to the manufacturer's specifications for that particular
altitude. Contact the company listed on the rating label when ordering high altitude constructed water heaters.
For any questions not covered in this booklet, contact your dealer or write to us at the address shown the rating plate affixed to the front of the
water heater.
This water heater has been designed and manufactured for the express purpose of heating and storing potable water and space heating. See page
23 for space heating instructions. Any use other than this purpose will release the manufacturer from any liability or warranty claims stemming from
the issue of this product. Consult local authorities.
INSTALLATION
Location- Select a location accessible to water lines, gas supply (type identified on the rating plate), an adequate open drain, and as close as practi-
cal to a chimney or gas vent. When installed, the water heater must be level. To prevent excessive heat loss through water piping, locate the water
heater as close as practical to the areas of greatest hot water usage. Do not locate the water heater where lines could be subjected to freezing
temperatures.
Adequate clearances shall be provided for easy access to controls by service personnel to enable proper cleaning, servicing and operation of the
water heater. Under no circumstances is the front of the water heater to be placed in a position where the burner tray assembly cannot slide out
for removal when servicing.
DO NOT STORE OR USE FLAMMABLE LIQUIDS, VAPORS, OR MATERIALS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
CAUTION
IMPORTANT
BEFORE PROCEEDING WITH THE INSTALLATION OF THIS WATER HEATER, READ AND THOROUGHLY UNDERSTAND THESE
INSTALLATION AND OPERATION INSTRUCTIONS. IF THERE ARE ANY QUESTIONS, THIS INSTALLATION SHOULD BE PERFORMED
BY A QUALIFIED SERVICE PERSON.