FACTS TO CONSIDER ABOUT THE LOCATION
Carefully choose an indoor location for the new water heater,
becausetheplacementisaveryimportantconsiderationforthe
safetyoftheoccupantsinthebuildingandforthemosteconomical
use of the water heater. This water heater is not for use in
manufactured (mobile) homes or outdoor installation.
Whetherreplacinganoldwaterheaterorputtingthewaterheater
inanewlocation,thefollowingcriticalpointsmustbeobserved:
1.Selectalocationindoorsascloseaspracticaltothegasventor
chimneytowhichthewaterheaterventisgoingtobeconnected,
andascentralizedwiththewaterpipingsystemaspossible.
2.Selected location must provide adequate clearances for
servicingandproperoperationofthewaterheater.
Keepcombustiblessuchasboxes,magazines,clothes,etc.,away
fromthewaterheaterarea.
Installationofthewaterheatermustbeaccomplishedinsuchamanner
that if tank or any connections should leak, the ow will not cause
damagetothestructure.Forthisreason,it isnotadvisabletoinstall
waterheaterinanatticorupperoor.Whensuchlocationscannotbe
avoided,asuitablemetaldrainpanshouldbeinstalledunderthewater
heater.Metaldrainpansareavailableatyourlocalhardwarestore.Such
ametaldrainpanmusthaveaminimumlengthandwidthofatleast2”
(51mm)greaterthanthewaterheaterdimensionsandmustbepiped
toanadequatedrain.Thepanmustnotrestrictcombustionairow.
Waterheaterlifedependsuponwaterquality,waterpressureandthe
environmentinwhichthewaterheaterisinstalled.Waterheatersare
sometimesinstalledinlocationswhereleakagemayresultinproperty
damage,evenwiththeuseofadrainpanpipedtoadrain.However,
unanticipateddamagecanbereducedorpreventedbyaleakdetector
or water shut-off device used in conjunction with a piped drain pan.
Thesedevicesareavailablefromsomeplumbingsupplywholesalers
andretailers,anddetectandreacttoleakageinvariousways:
• Sensorsmountedinthedrainpanthattriggeranalarmorturnoff
theincomingwatertothewaterheaterwhenleakageisdetected.
• Sensorsmountedinthedrainpanthatturnoffthewatersupply
totheentirehomewhenwaterisdetectedinthedrainpan.
• Watersupplyshut-offdevicesthatactivatebasedonthewater
pressuredifferentialbetweenthecoldwaterandhotwaterpipes
connectedtothewaterheater.
• Devicesthatwillturnoffthegassupplytoagaswaterheater
whileatthesametimeshuttingoffitswatersupply.
LOCATING THE NEW WATER HEATER
INSTALLATIONS INAREAS WHERE FLAMMABLE LIQUIDS
(VAPORS)ARELIKELYTOBEPRESENTORSTORED(GARAGES,
STORAGEANDUTILITYAREAS,ETC.):Flammableliquids(suchas
gasoline,solvents,propane[LPorbutane,etc.]andothersubstances
suchasadhesives,etc.)emitammablevaporswhichcanbeignitedby
agaswaterheater’spilotlightormainburner.Theresultingashback
andrecancausedeathorseriousburnstoanyoneinthearea,aswell
aspropertydamage.Ifinstallationinsuchareasisyouronlyoption,
thentheinstallationmustbeaccomplishedinawaythatthepilotame
andmainburnerameareelevatedfromtheooratleast18inches.
Whilethismayreducethechancesofammablevapors,fromaoor
spillbeingignited,gasolineandotherammablesubstancesshould
neverbestoredorusedinthesameroomorareacontainingagas
waterheaterorotheropenameorsparkproducingappliance.NOTE:
Flammablevaporsmaybedrawnbyaircurrentsfromotherareasof
thestructuretotheappliance.
Also,thewaterheatermustbelocatedand/orprotectedsoitisnot
subjecttophysicaldamagebyamovingvehicle.
This water heater must not be installed directly on carpeting.
Carpetingmustbeprotectedbymetalorwoodpanelbeneaththe
water heater extending beyond the full widthand depth ofwater
heaterbyatleast3”(76.2mm)inanydirection,orifthewaterheater
isinstalledinanalcoveorcloset,theentireoormustbecoveredby
thepanel.Failuretoheedthiswarningmayresultinarehazard.