Specifications

IMl66-107
System Programing
System Configuration -Timing Features
-
continued
1 Press
ITCM
W746%
1
Recall/Flash:
The system can generate either a line
zlisconnect (recall) or a host system
‘eature access signal (flash) depending
Jpon the programmed time.
Timed Hold Recall
After a call has been on hold for the
.
length of time set with this
programming feature, the system will
recall the station that placed the call on
hold.
Unanswered Call Transfer
Recall Time
A transferred call that remains
unanswered after the length of time
sei
inrith
this programming feature will
return to the transferring station for
answering.
I. Dial
12
WECALUFLSH
XxXx”
!.
Select time (LED On = Selected Time):
-
Dial
1
or Press
Al =
.08
sec.
“RECALLIFLSH
0.08”
-
Dial 2 or Press A2 = .30 sec.
‘RECALUFLSH 0.30”
-
Dial 3 or Press
A3 =
.50
sec.
WECALUFLSH 0.50”
-
Dial 4 or Press
A4 =
.60
sec.
“RECALUFLSH
0.60’:
-
Dial 5 or Press
A5
= .75 sec.
“RECALUFLSH 0.75”
-
Dial 6 or Press
A8
= .88 sec.
“RECALUFLSH 0.88”
-
Dial 7 or Press
A9
= 1 sec.
“RECALUFLSH 1
-
Dial 8 or Press
A10
= 1.5 sec.
“RECALUFLSH 1.50”
-
Dial
9
or Press
All = 2 sec.
“RECALUFLSH 2
-
Dial 0 or Press
Al2 = 3 sec.
“RECALUFLSH 3
a
3. Dial
+K
for configuration mode.
l-o change setting, repeat procedure and make different selection.
I. Dial 14
“HOLD RECALL XX-XX”
2.
Select time (LED On = selected Time):
-
Dial
1
or Press
Al = 30 sec.
.HOLD
RECALL 30
*
-
Dial 2 or Press A2 = 60 sec.
*HOLD
RECALL 60
-
Dial 3 or Press
A3 = 90 sec.
“HOLD RECALL 90
,a
-
Dial 4 or Press
A4
= 120 sec.
“HOLD RECALL 120
-
Dial 5 or Press
A5
= 180 sec.
“HOLD RECALL 180
-
Dial 6 or Press
A8 = 240 sec.
“HOLD RECALL 240
-
Dial 7 or Press
A9
= 300 sec.
“HOLD RECALL 300
-
Dial 8 or Press
Al0 = 360 sec.
“HOLD RECALL 360
-
Dial 9 or Press
Al 1 = 420 sec.
“HOLD RECALL 420
-
Dial 0 or Press
Al2 = 0 sec.
“HOLD RECALL 0
3. Dial
+R
for configuration mode.
To change setting, repeat procedure and make different selection.
.
1. Dial
11.
“TRANSFER RECALL
M
2. Dial
1
(station transfer recall).
“STA
XFR RCL XXX
‘-OR-
Dial 2 (department transfer recall).
“DEPT XFR RCL
XXX”
7. Choose transfer time (LED On = Selected Time):
-
Dial
1
or Press
Al
= 10 sec.
STA
XFR RCL 10
to
-
Dial 2 or Press A2 = 20 sec.
“STA
XFR RCL 20
*
-
Dial 3 or Press
A3 = 25 sec.
“STA XFR RCL 25
m
-
Dial 4 or Press
A4 = 30 sec.
“STA
XFR RCL 30
-
Dial 5 or Press
A5
= 45 sec.
“STA
XFR RCL 45
o
-
Dial 6 or Press
A8 = 60 sec.
“STA
XFR RCL 60
-
Dial 7 or Press
A9
= 90 sec.
“STA
XFR RCL 90
-
Dial 8 or Press
A10 = 120 sec.
“STA
XFR RCL 120”
-
Dial 9 or Press
Al 1 = 180
sec.
“STA
XFR RCL 180”
-
Dial 0 or Press
Al2 = 400
sec.
“STA
XFR RCL 400”
1.
Press
*
for next transfer recall feature.
5.
Press
*
*
for configuration mode.
ro change setting, repeat procedure and make different selection.
4-13