TDS

Technical Data Sheet
Blue Max® Tile & Floor
Ames Research Laboratories, Inc.
1891 16
th
St SE | Salem, OR 97302
888-345-0809 | productservices@amesresearch.com
8.2-TBMF 4/20/21
Stock Code
BMX3.5TILE
Packaging Information
3.5 Gallon Pail
Characteristics
Blue Max® Tile & Floor is a tough blue elastomeric waterproofing
rubber. It can be used in both residential and commercial
applications where a waterproofing membrane is needed during the
application of floor and wall tiles. Blue Max® Tile & Floor meets
Uniform Plumbing Code specifications for use as a shower pan liner.
VOLUME SOLIDS
46%
WEIGHT PER GALLON
ASTM D1475 8.36 lbs.
ADHESION TO VARIOUS
SUBSTRATES
CMU - ASTM D4541 Method B 80.2 psi
exceeds minimum
Hardie Board ASTM D4541 Method B 198.8
psi exceeds minimum
DensGlass ASTM D4541 Method B 43.3
exceeds minimum
COLOR
Translucent Blue
COVERAGE
1 gallon per 25 sq. ft. per coat dependent on
system application (2 coat minimum for
sprayer & 4 coat minimum for roller)
DRY TIME
Allow 24 hours between coats
CURE TIME
ELONGATION
DRY FILM THICKNESS
(@ 1 GAL/25 SQ. FEET)
7-10 days
ASTM D2370 up to 1200%
15 Mils per coat (30 Mils total DFT required)
FLASH POINT
>200°F
HUMIDITY
Best applied at 50% humidity or below
AIR PERMEANCE
ASTM E2178 Air Permeance 0.00010 cfm/ft² @
1.56lb/ft²
SEAM STRENGTH
ANSI 118.10 Section 4.2 114 lb./in-Perpendicular
to Seam 46.3 lb./in-Parallel to Seam
MOLD & MILDEW
RESISTANCE
ANSI 118.10 Section 4.1 No Growth
PH AS SHIPPED
ASTM E70 9.0-9.5
BREAKING STRENGTH
ANSI 118.10 Section 4.3 1.540 psi Machine
direction 512 psi Cross Direction
SHELF LIFE
24 Months Unopened
DIMENSIONAL STABILITY
ANSI 118.10 Section 4.4 -0.17% (70°C) -0.17% (-
26°C)
V.O.C CONTENT
< 1 g/l
VAPOR PERMEABILITY
ASTM E96 Desiccant Method 0.117 perms.
Water Method 0.49 perms
VISCOSITY
ASTM D2196 4100-5100 cps spindle # 6@100
rpm
SHEAR STRENGTH
ANSI 110.10 Section 5.0 138 psi (7-day)
89.4 psi (7- day water immersion)
125 psi (Four-Week)
140 psi (twelve-Week)
76.6 psi (100 day water immersion)
Compliance
SCAQMD
Yes
LEED®V4 & V 4.1
EMMISIONS
Yes
LEED® V4 & V4.1 V.O.C
Yes
CARB & CARB SCM
2007
Yes
OTC & OTC PHASE II
Yes
Surface Preparation
Remove all contaminants, chalk, loose paint, rust, debris, and
other foreign matter that can impede adhesion
Surface must be totally dry before coating
Application Methods
Brush: Nylon/polyester
Roller: 3/8" - 1/2" nap nylon/polyester
Sprayer: Always use airless equipment
o Small Projects Apply 1 gal per battery charge (i.e. Graco
TC Pro handheld battery powered airless). 2000psi. Tip
size: 0.412 - 0.416. No hose needed, 32 oz. capacity reservoir.
o Mid-Sized ProjectsFlow rate of 0.60 GPM (i.e. Graco 495
airless). 2500 - 3000 psi. Tip size 0.412 - 0.521. Hose size 1/4
in.
o Large Projects Flow rate of 1.0+ GPM (i.e. Graco 695
airless). 2500 to 3000 psi. Tip size .417 to .625. Hose size 1/4
in.- 3/8 in.
Application Instructions
Review product Application Guide before proceeding. Contact
Ames Research Laboratories Technical Service Department for
questions pertaining to the coating system application and
required coating film thickness. Conduct a test patch to ensure
proper adhesion
Ensure area to be filled is clean of debris and loose material.
Use a wire brush if needed to remove loose material
Please refer to Application Guide for film thickness
requirements to meet ANSI 118.10 and IAMPO requirements
Do not allow product in packaging to freeze
Do not install in area expected to reach 180°F or above
Do not use as a wear surface: the membrane must be covered
with tile or other permanent flooring
Do not apply over wet substrates
See page 2 for detailed application steps
Disclaimer
The information and specifications set forth in this Technical
Data Sheet are based on tests conducted by or on behalf of
Ames Research Laboratories, Inc. All information is subject to
change and pertains to the product available at time of
publication. Please contact Ames Research Laboratories to
receive the most recent Technical Data Sheet.
Clean-up, Storage & Disposal
Clean up application equipment, tools, spills, hands
immediately after use with water
Store unused product in the original container tightly sealed
Dispose of this product in accordance with local, state, or
federal requirements
Protect from freezing
Cautions
Do not take internally
Keep out of reach of children
Avoid contact with skin and eyes
Use hand and eye protection when using this product
Wash with soap and water after contact with skin
If eye-contact occurs rinse with clean water and seek medical
advice if symptoms continue

Summary of content (2 pages)