Characteristics
Maximum-Stretch® is a white elastomeric, acrylic, rubberized roof
coating and sealant with 650% elongation that resists cracking and
peeling. With 88% light reflectivity the bright white finish reduces
surface temperatures resulting in a reduced cooling cost and
thermal expansion and contraction. Designed for low-slope roof
maintenance on metal, built-Up roofing, rolled roofing, modified
Bitumen concrete, EPDM, and wood.
VOLUME SOLIDS
33%
WEIGHT PER GALLON
ASTM D1475 9.67 lbs./ gallon
ADHESION TO
VARIOUS SUBSTRATES
ASTM D903 PLI> 5.00
Dry Galvanized Steel, Plywood,
Concrete, Aluminum
COLOR
White & Custom Colors available
COVERAGE
1 gallon per 100 sq. ft. per coat
(minimum 2 coats required)
DRY FILM THICKNESS
(@ 1 GAL/100 SQ. FEET)
5.3 Mils per coat
(Minimum 10.6 Mils total DFT required)
DRY TIME
At 40° - 80° F 2-8 hours.
Allow 24 hours between coats
CURE TIME
7- 10 days
ELONGATION
ASTM D2370 up to 650%
FLASH POINT
>200°F
HUMIDITY
Best applied at 50% humidity or below
INITIAL EMITTANCE
ASTM C1371 - 0 .85
INITIAL REFLECTANCE
%
ASTM C1549 - 88.0%
MOLD & MILDEW
RESISTANCE
ASTM G21 Excellent
PH AS SHIPPED
ASTM E70 8.75-9.25
REFLECTANCE %
AFTER 3 YEARS
ASTM C1549 - 75.63%
SHELF LIFE
24 Months Unopened
TEAR RESISTANCE
ASTM D624 77.0 lbs./in
V.O.C CONTENT
< 25 g/l
VAPOR PERMEABILITY
ASTM E96 Desiccant Method 0.96
perms
VEHICLE TYPE
Acrylic/Styrene Butadiene
VISCOSITY
ASTM D2196 6000-7000 cps spindle #
6@100 rpm
Compliance
SCAQMD
Yes
ACCELERATED LOW
TEMPERATURE FLEX
ASTM D522 Type I Pass
ASTM D522 Type II Pass
Surface Preparation
All surfaces must be sound and free of frost, dirt, grease, oil, spalled
areas, loose nails, screws, sharp protrusions, or other contaminants that
will hinder the adhesion of the membrane installation. Clean loose dust
and dirt from the surface by brushing or wiping with a clean, dry cloth
brush or broom. Do not cover wet or soft spots until dry or replaced.
Surface must be completely dry before coating.
Application Methods
Apply between 50° - 90° F on a warm dry surface. Surface temperature
must be 5° F higher than the dew point and rising
Brush: Nylon/polyester
Roller: 3/8" - 1/2" nap nylon/polyester
Sprayer: Always use airless equipment (see spray application section
below for details)
Application Instructions
Review product Application Guide before proceeding. Conduct a test
patch to ensure proper adhesion.
Maximum-Stretch® should be applied on a properly and adequately
drained roof and the roof surface must be clean, dry and in savable
condition. Some areas may require periodic preventative maintenance.
Ames Research Laboratories Technical Service Representatives are
available to assist in determining the correct Maximum Stretch® Roof
System for your specific roof. All specifications are suggestions only.
Spray or pour out Maximum-Stretch® onto surface. Spread in 1- or 2-
gallon increments if applying by squeegee, push broom or roller
Even up the coating application with a roller as needed to maintain
a uniform thickness
Work on manageable sections of roof allowing you time to properly
apply the materials prior to materials beginning to dry
If spraying it may be advantageous to back roll through the first coat
during application to infill rough surfaces. Always contact Technical
Services when in doubt
Spray Application
Airless Equipment sizing should be a flow rate of 1.0 2.0 GPM, 2500
to 3000psi, Heavy Duty Reverse-clean tip (without diffuser pin) sizes
629 (12” fan .029 orifice size) to 633 (12” fan -033 orifice size) Hose size
3/4” reduced to 1/2before connection to gun swivel
If airless has a machine filter in addition to the intake rock screen we
recommend either a 40-mesh filter or temporarily removing the
machine filter cartridge altogether.
Airless equipment should be cleaned after use without delay
Contact Ames Research Laboratories Technical Service Department
for more information, guidelines, and recommendations on spray
application.
Disclaimer
The information and specifications set forth in this Technical Data
Sheet are based on tests conducted by or on behalf of Ames Research
Laboratories, Inc. All information is subject to change and pertains to
the product available at time of publication. Please contact Ames
Research Laboratories to receive the most recent Technical Data Sheet.
Clean-up, Storage & Disposal
Clean up application equipment, tools, spills, hands immediately
after use with water
Store unused product in the original container tightly sealed
Dispose of this product in accordance with local, state, or federal
requirements
Protect from freezing
Cautions
Do not take internally
Keep out of reach of children
Avoid contact with skin and eyes
Use hand and eye protection when using this product
Wash with soap and water after contact with skin
If eye-contact occurs rinse with clean water and seek medical advice
if symptoms continue