TDS

Technical Data Sheet
Elasto-Barrier®
Ames Research Laboratories, Inc.
1891 16
th
St SE | Salem, OR 97302
888-345-0809 | productservices@amesresearch.com
8.2-TEB 4/20/21
Stock Code
SEB Series
Packaging Information
1 Gallon Pail
5 Gallon Pail
55 Gallon Drum
250 Gallon Tote
Characteristics
Elasto-Barrier® is a waterborne elastomeric primer primarily used
for roofs. Elasto-Barrier® can be used in areas subjected to ponding
water, and in conjunction with embedding fabrics to reinforce roof
areas. Elasto-Barrier® must be top coated with a suitable Ames®
UV-Resistant product.
VOLUME SOLIDS
41% ± 2%
WEIGHT SOLIDS 46% ± 2%
ADHESION TO
VARIOUS SUBSTRATES
ASTM D3359 Cross Hatch Adhesion
Dry Concrete, Plywood, Pressure
Treated Plywood, Cedar, Galvanized
Steel, Cold Rolled Steel, Aluminum
COLOR Gray
COVERAGE
1 gallon per 66 sq. ft. per coat
CURE TIME
7-10 days
DRY FILM THICKNESS
(@ 1 GAL/66 SQ. FEET)
10 Mils
DRY TIME
At 40° - 80° F 2-8 hours
Allow 24 hours dry time between coats
ELONGATION
ASTM D6083 ASTM D412 up to 1200%
at 20 Mils DFT
FLASH POINT
>200° F
HUMIDITY Best applied at 50% humidity or below
PH AS SHIPPED ASTM E70 9.4-9.9
UV SENSITIVITY
Yes, must be top coated or covered if
exposed to UV light
SHELF LIFE 24 Months Unopened
PVC
8.5%
V.O.C CONTENT
< 5 g/l
VAPOR PERMEABILITY
ASTM E96 Desiccant Method 0.18
perms
VEHICLE TYPE
Acrylic/Neoprene/Styrene Butadiene
Blend
VISCOSITY
ASTM D2196 5000-6000 #6 Spindle @
100rpm
Compliance
SCAQMD
Yes
OTC & OTC PHASE II Yes
CARB & CARB SCM
2007
Yes
LEED® V4 & V 4.1
EMISSIONS
Yes
LEED® V4 & V4.1 V.O.C.
Yes
Surface Preparation
Pressure-wash or scrub, and rinse existing roof with clean water.
Do not use soap or detergent. Surface must be totally dry before
beginning work/coating
Application Methods
Apply between 50° - 90° F on a warm dry surface. Surface
temperature must be 5° F higher than the dew point and rising
Brush: Nylon/polyester
Roller: 3/8" - 1/2" nap nylon/polyester
Sprayer: Always use airless equipment (see spray application
section for details)
Application Instructions
Check existing fasteners at flashings, nailed down cap sheet
seams, and other roof mounted items refastening or replacin
g
f
asteners as needed
On all roof types: overlapped seams between roof sheeting,
flashing details, mechanical equipment curbs, pitch pockets,
cable mounts and drain transitions all need to be counter flashed
with polyester fabric installed into a wet bed of Elasto-Barrier®
Allow embedded flashing details to dry 24 hours before
beginning first body coat of Elasto-Barrier®
Apply 1
st
coat of Elasto-Barrier® at a rate of 66 sq. ft./gal. and allow
to dry a minimum of 8 hours. Note: If the substrate is rough or
irregular an additional coat applied at 66 sq. ft/gal may be
required
After waterproofing layer(s) have dried, apply a 2
nd
coat of Elasto-
Barrier® at a rate of 90 sq. ft./gal. While wet, roll out a layer of
reinforcing polyester fabric into the wet material, remove air
pockets and wrinkles, overlap the fabric a minimum of 4 inches
and roll over the still wet embedded fabric to completely saturate
the fabric as needed up to 220 sq. ft./gal.
Once the embedded polyester fabric has dried a recommended
24 hours, apply a 3
rd
coat of Elasto-Barrier® at a rate of 66 sq. ft/gal
The Elasto-Barrier® Fabric Reinforced System should measure 30
mils dry film thickness when properly applied. Always check
previously applied coat for dryness before walking on the coating
surface
Some areas may appear to be dry be cautioned that areas of
spray overlap, or additional thickness may take longer to dry. Dry
times are dependent on weather conditions
A mil gauge (wet mil gauge) should be used to check the
thickness during application of each coat
As with all construction materials, care should be taken to protect
membrane against being soiled or punctured prior to the
installation of subsequent products
After 72 hours of exposure, protect from UV exposure by direct
sunlight
Spray Application
Airless Equipment sizing should be a flow rate of 1.5 to 2 GPM,
2500 to 3000psi, Heavy Duty Reverse-clean tip (without diffuser
pin) sizes 629 (12” fan .029 orifice size) to 633 (12” fan -033 orifice
size) Hose size 3/4” reduced to 1/2 before connection to gun
swivel.
If airless has a machine filter in addition to the intake rock screen
we recommend either a 40-mesh filter or temporarily removing
the machine filter cartridge altogether.
Airless equipment should be cleaned after use without delay
Disclaimer
The information and specifications set forth in this Technical Data
Sheet are based on tests conducted by or on behalf of Ames
Research Laboratories, Inc. All information is subject to change
and pertains to the product available at time of publication. Please
contact Ames Research Laboratories to receive the most recent
Technical Data Sheet.
Clean-up, Storage & Disposal
Clean up tools, spills, hands immediately after use with water
Store unused product in the original container tightly sealed
Dispose of this product in accordance with local, state, or federal
r
equirements
Protect from freezing
Cautions
Do not take internally
Keep out of reach of children
Avoid contact with skin and eyes
Use hand and eye protection when using this product
Wash with soap and water after contact with skin
If eye-contact occurs rinse with clean water and seek medical
advice if symptoms continue