Manual
17
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.com
4.3: Application Specific Objects
4.3.1: Position Object (Class ID = 100)
There is a single instance of the position object for the DeviceNet Resolver. No class attributes are 
supported. All the instances are gettable and settable. The table below shows the values:
Attribute ID  Access Rule  Name  Data Type  Value 
1  Get/Set  Magnet Position  UINT  Current Position 
2  Get/Set  Scale Factor  UINT  Current Scale Factor 
3  Get/Set  Direction  USING  Current Direction 
Valid position values range from 0 to the current scale factor. Valid scale factor values range from 2 to 
4096. Direction value 0 indicates that the counts will increase clockwise. Direction value 1 indicates that the 
counts will increase counter-clockwise.
4.3.2: Setpoint Object (Class ID = 101)
There are eight instances of the setpoint object in the DeviceNet Resolver. No class attributes are 
supported. All setpoint position data is gettable and settable. The setpoint status is gettable.
Attribute ID  Access Rule  Name  Data Type  Value 
1  Get  Setpoint Status  BOOL  0x00 
2  Get/Set  Setpoint On Position  UINT  0x0000 
3  Get/Set  Setpoint Off Position  UINT  0x0000 
Valid setpoint values range between, and include, zero and the scale factor. 
 (i.e. < setpoint < scale factor)
4.3.3: RPM Object (Class ID = 102)
There is a single instance of the RPM object for the DeviceNet Resolver. No class attributes are supported. 
All the instances are gettable but not settable. The table below shows the values:
Attribute ID  Access Rule  Name  Data Type  Value 
1  Get  RPM  UINT  Current RPM Value 