Manual

15
Installation and Maintenance Manual
Chapter 3: Programming
3.18: Programming 1995 PLS for Linear Speed
A) Unit must be in the Program mode.
B) Select the number of circuits that will be offset based on RPM. The affected circuits will always
start with CIR# 1 and will follow in ascending sequence to the number specified. Depress:
ENT
CIR#
-
-
(1 thru 5)
- -
80
NOTE: LS5 cannot be programmed for Linear Speed if it is set for Motion detect. See Section 3.13:
Motion Detector
NOTE: On units built prior to November 1, 1990, the Linear Speed Offset had only a single ramp
offset.
CIR# - 81 - ENT - CIR ON = Offset Amount
CIR# - 81 - ENT - CIR OFF = RPM Value
Codes 501 - 516 will result in a programming error on this older software.
C) Starting with Circuit 501, program the amount of offset and RPM point for the first offset ramp.
Next use Circuit 502 to program both values for the second offset ramp. Continue with Circuit
503 and onward in ascending order until all desired ramps are programmed.
1)
CIR#
-
501 thru 516
-
CIR ON
-
-
(Specify the total amount of offset
from the original output settings) -
ENT
CIR#
-
501 thru 516
- CIR OFF-
-
(Specify the RPM at which the
above specified amount of offset occurs.)
ENT
2)
NOTE: If CIR# 501 - CIR OFF is set to zero, all linear speeds will be disabled.
3.19: Minimum Speed Disable
The Minimum Speed Disable sets the minimum speed at which the Linear Speed will affect the outputs.
Below the programmed speed, the Linear Speed outputs will not be enabled.
The Minimum Speed feature is programmed as follows:
A) Unit must be in the Program mode.
B) Depress . This sets the Minimum Speed at
which the Linear Speed will affect the outputs. Below the programmed speed, the Linear
Speed outputs will not be enabled.
ENT
CIR#
-
-
(RPM Value)
-
ENT
-
85
ENT
.
.
ENT