Chapter 3: Programming
Installation and Maintenance Manual
18
PROGRAMMING AND MONITORING
To monitor press stopping time, depress CIR# - 174 - ENT. Stopping time will be displayed in milli-
seconds from 001 to 999. Three decimal points indicate a stopping time in milliseconds, a single
decimal point, two places to the left, will indicate a stopping time in seconds to one hundredth of a
second. If the customers preset stopping time is exceeded, the display and decimal(s) will flash. They
will continue to flash until the brake monitor output has been reset.
To monitor press stopping angle, depress CIR# - 175 - ENT. Stopping distance will be displayed in
degree increments. If the stopping time is exceeded while in the stopping angle mode, the display will
flash. It will continue to flash until the brake monitor relay has been reset.
When operating in either of the above modes, the display will maintain the stopping data until initiation of
the next timing cycle. At this point, the display will indicate dashes until new data is available. Depres-
sion of the POS or RPM keys will return the display from this operating mode.
To program the maximum acceptable stopping time, depress CIR# - 173 - ENT. The time data can be
programmed from 001 to 999 milliseconds. If the programmed stopping time is exceeded, the brake
monitor output (LS6) will de-energize until the fault check input is opened and then closed again.
NOTE: If you are using the fault check option, the fault check relay will cycle OFF/ON when the
brake fault output is reset.