Manual

Chapter 9: Specifications
Installation and Maintenance Manual
28
Chapter 9: Specifications
9.1: 1995 Micro-Set PLS Programmer
9.2: Mechanical Relay (Single Pole, Double Throw)
Resolution -12 Bit (4096)
Scale Factor -360
Scan Time -Standard 335 µseconds
Temperature -32°F to 125°F (Operating)
Range -0°F to 150°F (Storage)
Operating Voltage -110/120V AC 50/60 Hz 300 mA
INPUTS
Transducer -Resolver accurate to ±3 arc minutes provides resolution of 1
part in 4096, 2800 RPM maximum speed.
Logic -Fault check and security 5V DC at 10mA. May be operated
by isolated contact, current sourcing or current sinking device.
OUTPUTS -Plug-in relays listed below
Contact Relay -10 Amp Isolated Contact
Pick-Up -2 ms
Drop-Out -15 ms
9.3: AC Solid-State (Single Pole, Normally Open)
Maximum Load -1 Amp
Load Voltage Range -70 - 250V AC Zero Voltage Switching
Leading Current -3 mA at 120V AC
Voltage Drop w/Output On -3.0V RMS or Less
Inputs -N.O. and Common
Operate & Reset Time -1/2 cycle of line voltage max. +1ms or less