User guide
11
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.com
Figure 3-2: Current Sourcing
NOTE: 952A-C is current 
sourcing, which allows the 
current to ow from the LDT 
into the user’s equipment.
Differential Input
 Power    +
 Supply
    _
952A
LDT
+ Input
- Input
Customer Supplied Power
Power Supply Common
Position Output
Position Common
Program Input
Single Ended Input
 Power    +
 Supply
    _
952A
LDT
+ Input
Common
Customer Supplied Power
Power Supply Common
Position Output
Program Input
3.5: 952A (Analog)
3.6: 952 CP (Control Pulse)
The control pulse signal interface of the BlueOx 
digital output series is a differential RS-422 output. 
The maximum cable length for the differential digital 
LDTs is 1,500 feet. To initiate a start pulse, an 
external device is used. This start pulse should be 
1.0 microsecond in duration. After the start pulse 
1 MICROSECOND (RECOMMENDED)
0.2 MICROSECONDS (MINIMUM)
+ INPUT (START PULSE)
TIME BETWEEN PULSES IS PROPORTIONAL TO
DISTANCE BETWEEN MAGNET AND HEX HEAD
+ OUTPUT (STOP PULSE)
Figure 3-3: 952CP Control Pulse
is received, the LDT will generate a stop pulse of 
1.0 microsecond in duration. The time between 
the leading edge of the start pulse to the leading 
edge of the stop pulse is the proportional distance 
between the magnet to the hex head. The order of 
these two pulses is illustrated in Figure 3-3. To wire 
the 952CP, see Figure 3-7. For proper grounding 
information, see the beginning of this chapter.