3.7: 952 VP (Variable Pulse)
The variable pulse signal interface of the BlueOx 
digital output series is a pulse width modulated 
signal (RS-422). The maximum cable length for the 
differential LDTs is 1,500 feet. This LDT can also 
be congured for external or internal interrogation. 
External interrogation is when an external device 
connected to the LDT generates a start pulse. This 
start pulse should be a minimum of 1.0 microsecond 
in duration. Within 50 nanoseconds after the leading 
edge of the start pulse has been received, the LDT 
will generate an output pulse. The duration of the 
Figure 3-4: 952VP with External Interrogation
INPUT (INTERROGATION)
1 MICROSECOND (RECOMMENDED)
0.2 MICROSECONDS (MINIMUM)
WIDTH OF PULSE IS PROPORTIONAL TO
DISTANCE BETWEEN MAGNET AND HEX HEAD
OUTPUT PULSE
WITHIN 50 NANOSECONDS AFTER INTERROGATION
TO DISTANCE BETWEEN MAGNET AND HEX HEAD
OUTPUT PULSE
LOW OUTPUT VARIES DEPENDING ON LENGTH 
PROGRAMMED VIA DIP SW2 SWITCHES 1-6 
WIDTH OF PULSE IS PROPORTIONAL 
TO DISTANCE BETWEEN MAGNET AND HEX HEAD
output pulse is proportional to the distance from 
the magnet to the hex head. The order of these two 
pulses is illustrated in Figure 3-4. The 952VP can 
also generate internal interrogations. This LDT will 
continually output pulse width modulated signals. 
As with a 952VP using an external interrogation, 
the duration of this output pulse is proportional to 
the distance from the magnet to the hex head. This 
is illustrated in Figure 3-5. To wire the 952VP, see 
Figure 3-7. For proper grounding information, see 
the beginning of this chapter.
Figure 3-5: 952VP with Internal Interrogation