A Tri-color LED is conveniently located next to the 
connector to help with set-up and diagnostics.
Diagnostic LED
LED Color Description
None No power to LDT
Green Magnet signal detected and within programmed 
range.
Yellow Magnet signal detected, but magnet is outside of 
programmed range. 
NOTE: Magnet can be programmed in this range 
if desired.
Red No magnet signal detected. Make sure magnet 
is on the rod and within the active area. Move 
magnet back into the range and cycle power.
If a problem exists after reading this section, please 
contact our technical support department. 
General Checks
Make sure that the magnet is located within the 
LDT’s active stroke area. Keep in mind that the LDT 
is programmable over the entire active stroke area. 
Captive magnet assemblies should be positioned 
so that they can move freely over the entire area of 
the active stroke without binding or pushing on the 
rod end. Non-captive magnet assemblies should be 
situated so that the magnet is no farther than 0.2” 
from the rod at any point in the magnet assembly’s 
movement.
Optional Remote Tester & Programmer
The battery operated remote tester / programmer is 
available in either a voltage or current model. P/N 
SD0528810 is designed for voltage 
units while SD0528811 is for current 
units. Both units are designed to 
work with connector option S only. 
These units are typically used to 
demonstrate the functionality of the 
LDT in the eld, however, they can 
be used as a handy troubleshooting 
/ programming device.
1. Attach the 5 pin Euro connector 
to the VMAX.
2. Push the toggle switch to the ON position to power 
the LDT.
3. Place magnet assembly where Zero is to be 
located, but within the active region of the probe.
4. Push the black Zero button for 4 seconds, 
release for 1 second. Within 5 seconds, push 
the Zero button again. This completes the Zero 
programming process.
5. Place magnet assembly where Span is to be 
located, but within the active region of the probe.
6. Push the black Zero button for 4 seconds, release 
for 1 second. Within 5 seconds, push the Span 
button. 
NOTE: This time the Span button is pushed for the 
nal programming step.
 This completes the programming process.
Appendix A: Troubleshooting
NOTE: Ferromagnetic material (material readily 
magnetized) should be located no closer than 0.25” 
from the magnet or LDT rod end. This includes 
mounting brackets, magnet spacers, magnet brackets, 
and mounting screws. Ferromagnetic material can 
distort the magnetic eld, causing adverse operation or 
even failure of the LDT.
Check all LDT wires for continuity and/or shorts. It 
is preferred that the cable between the LDT and the 
interface device be one continuous run. If you are 
using a junction box, it is highly recommended that the 
splice junction box be free of AC and/or DC transient-
producing lines. The shield should be carried through 
the splice and terminated at the interface device end.
Power Supply Checks
This section will help you to determine if your power 
supply is adequate for the LDT to operate properly, or 
if the LDT’s cable has a short or open.
In order for the VMAX to operate properly, the external 
power supply must provide a level between 7-30 VDC. 
A power supply providing voltage above this specied 
range may damage the LDT. A power supply providing 
power below this specied range will not be sufcient 
Optional In-Line Programmer
The 955-1409 is a remote 
programmer that can help 
simplify the programming 
process. The programmer 
is a portable device 
that can be temporarily or permanently 
installed in series with the VMAX with 
connector option S. 
1. Remove the 5 pin cordset to the LDT.
2. Attach the existing cordset to the 955-1409 
programmer.
3. Attach the other end to the LDT.
4. Apply power to the LDT.
5. Place magnet assembly where Zero is to be 
located, but within the active region of the probe.
6. Push the Zero button for 4 seconds. Release the 
button for 1 second. Within 5 seconds, push the 
Zero button again.
7. Place magnet assembly where Span is to be 
located, but within the active region of the probe.
8. Push the Zero button for 4 seconds. Release the 
Zero button for 1 second. Within 5 seconds, push 
the Span button.