Service manual
EBS - MARK II
1-68
F - MAINTENANCE
Released:01/2013 
E-mail:  service@amfreece.cz;  webside:  amfreece.com 
Phone: +420 582 309 146; Fax: +420 582 360 606
1.6. Cleaning the fan:
Loosen the screws   on the control 
cabinet, use a cross screwdriver. Loosen 
4 screws 
 on the fan grid  . 
 ATTENTION! When loosening the last 
screw hold the fan with the grid 
 inside 
the cabinet to avoid its fall into the control 
cabinet. Put the screwdriver into the 
aperture on the grid 
, press it through 
the cleaning insert   and then push out 
the plastic cover of the grid  . Take out 
the cleaning grid. Shake or draw out the 
insert, in case of larger dirt wash in a 
detergent. Carry out similar maintenance 
also on the back grid 
.
1.7. Maintenance of the air regulator
It includes the check of the condensate and the possible replacement 
of the filtering patron 
. The level of the condensate inside the 
sludge pit   should not reach the level above 10mm under the level 
of the filtrating patron  . The lower nut collar   signalizes this 
height. Loosen the emptying screw   to drain the condensate and 
then tighten the screw again.
If the air flow worsens replace the filtrating patron 
 after you have 
shut off the air. Screw out the sludge pit   anticlockwise and vent. 
Unscrew the nut  , this releases the filtrating patron  , replace it 
with a new one and then mount the device in the reverse order.
1.8. Visually check the mechanisms, mainly in the area of the sewing. No threads and fabric 
can be left in this area.
1.9. Put the covers in their operating position and check the machine operation according to 
section C.