B - MACHINE ASSEMBLY
3. THE DISPLAY POSITION CHANGE WHEN THE HEAD POSITION IS CHANGE
(the universal table only)
a) To change the crosswise table to the parallel table
1. Remove the cable fitting Ê, screw Ë, plug Ì and screws Í.
2. Disconnect the cable Î and display Ï.
3. Remove the display holders Ð, cable Î and display Ï.
4. Remove the screws Ñ, washers Ò and display box Ó.
5. Remove the nuts and insert the plugs Ì into the holes where the screws were before (one of the
plugs is in the drawer of the table).
6. Remove the plugs from the lower side of the display box Ó and place them into the side holes of the
display box.
7. Using the screws Ñ and washers Ò, install the display box Ó on the upper side of the machine head.
Place the screws and washers on the lower side of the display box, not on the side as they were before.
8. Insert the display holders Ð and display Ï to the display box. Fix it by screws Í.
9. Connect the cable Î and display Ï.
Note: The cable fitting Ê, screw ➋ and nuts are not used on the parallel table