E - MACHINE ADJUSTMENTS
4. NEEDLE BAR
1. Needle bar crank position
Turn the handwheel and loosen the screw in the
needle bar crank . Turn the handwheel until the
needle bar reaches the upper position. Pulley screw
on the main shaft should be in the same line with
screw. Tighten the screw .
NOTE: The needle bar should be in the top dead
center position when the screw is at 12 o‘clock. To
check, turn the handwheel clockwise and counter
clockwise. The needle bar must move downward in
either direction. The needle makes its first stroke into
the right side of the throat plate.
2. The needle bar height adjustment
Adjust the needle bar height to 16 mm (5/8“) from
the surface of the throat plate to the lower edge
of the needle eye. Use height gauge .
Loosen the set screw and move the needle bar up
or down as necessary.
the first stitch direction