E - MACHINE ADJUSTMENTS
13. HEAD CLAMP FOOT ADJUSTMENT
1. Adjustment for clamp height
Be sure that air supply is switch on and the clamp foot is opened. If clamp foot is not opened, push the
clamp Up / Down button.
a) loosen the nut Ê
b) turning the screw ➋ clockwise lowers the clamp foot mechanism Ì to clamp mat Í
c) tighten the nut Ê
NOTE: Correct height is when the underside of the clamp foot is slightly lower than the point of the
needle in the home position.
2. Clamp foot to the center of the needle
Be sure that the clamp foot is closed. If clamp foot is not closed, push the clamp Up / Down button.
a) turn the handwheel to be sure that needle does not hit the clamp foot Ì. If it hits:
b) push the clamp Up / Down button to open the clamp foot
c) loosen the screw Î and get the clamp foot arm further from the needle and tighten the screw Î
d) to check this adjustment, turn the handwheel when the clamp foot is closed. The needle must
not hit the clamp foot
S4000 TKF