Service manual
S-4000 TKF, LS Omron
1-48
Released 12/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
F - MACHINE MAINTENANCE
Warning: - Check for damage to electrical cables
- Check safety covers for damage and replace immediately if needed
- Keep your hands out of the sewing area
- Do not modify the machine in any way, which could eliminate safety parts
- Do not attach external lights or other devices to the machine´s electrical system
Caution: - Do not neglect periodic maintenance.
- If you have fault in electrical power supply, switch off the operating switch (circuit
breaker).
- Do not damage, correct and remove safety labels.
- Do not work with the machine when you are under the influence of the drugs or
alcohol.
- User has to ensure the lighting of the working area minimal 750 Luxes.
1. MACHINE CLEANING AND MAINTENANCE
1. Switch the power off and disconnect air
supply.
2. For cleaning and oiling, remove the
cover ➊ and take out the clamp foot
mechanism ➋.
Clean the clamping area of any fabric and
thread lints.
3. Open the needle bar cover ➌ and
clean any thread lints from the
guides ➍ and thread tension ➎.
4. Clean any thread lints and fabric from the
sewing area - throat plate, loopers.
5. Lubricate the machine according to
the section F 4.