Service manual
S-4000 TKF, LS Omron
1-50
Released 12/2009
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
F - MACHINE MAINTENANCE
2. PERIODIC MAINTENANCE
once a day (8 hours of operation) - cleaning of the sewing mechanism area and inner frame of the
- machine
- lubrication of mechanisms - see area F4.
once a week (40 hours of operation) - visual check - external and internal mechanisms
- fill oil into reservoir with oil level indicator, or sooner if required
once a month (160 hours of operation) - check of the clearance in sewing mechanism drive
- check of the screw connections tightening (obtain values below)
- check of condensate in regulator
- check of dirty of cleaning pads in control box
Rec
ommended values for srews tihtening ( N m ) :
M3 0,5 0,6 0,8
M4 1,2 1,5 2,0
M5 2,5 3,0 4,0
M6 4,0 5,0 7,0
M8 8,0 16,0
M10 10,0 30,0