Service manual

1-73
S-104-100
Revised 09/2004
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
LOOPERS AND SPREADERS
5. Loosen screw A and move the left hand looper 1/2 the distance noted in step 3. Once the looper has
been moved, re-tighten screw A. Step 2 through 5 may need to be repeated in order to obtain equalization
of the loopers.
6. Moving the left hand looper away from the needle will bring the right hand looper closer to the needle.
Moving the left hand looper closer to the needle will move the right hand looper away from the needle.