A9240-A-004-485 User Manual 
3.6 Auxiliary I/O Interface   
A9240-A-004-485 RFID reader provides 1 set of auxiliary input and four sets of auxiliary 
outputs.    All auxiliary I/O are optically isolated.    The +V and –V terminal blocks must be 
connected to +12V DC and ground in order for the auxiliary I/O to function properly.    Other 
voltage level should not be used.    User sensors, alarms, warning lights, or PLC 
(programmable logic controller) can be connected to the A9240-A-004-485 RFID reader to 
form a flexible infrastructure. 
Optically Isolated Input 
The optically isolated input terminals (IN1) are to be connected to external switch only. The 
external switches are either open or close.    There should not be any voltage or current 
draining / supply on these contacts.    The reader will sense the states of the external switch 
on these input terminals by means of optical coupler.    The second set of optically isolated 
input terminals (IN2) is reserved for future usage.    This auxiliary input should not be used.   
Please contact AMIC regarding the usage of input terminals, IN2. 
Optically Isolated Output 
There are four sets of optically isolated output ports.    Each output port consists of two 
terminals.    Each output port’s terminals are either connected or disconnected through the 
internal relay controlled by optical coupler.    The electrical characteristics of the relay are 
described as follows: 
  Relay Contact capacity (Resistive load):       3A/125VAC or 3A/30VDC 
  Relay Contact capacity (Inductive load):  0.3A/125VAC or 0.3A/30VDC 
 Relay Contact resistance:  100m
Ω
 Max. 
 Relay Operation time:  5msec Max. 
 Relay Release time:  5msec Max. 
  Max. Relay ON/OFF switching (Mechanically):  300 operation/min 
  Max. Relay ON/OFF switching (Electrically):  30 operation/min 
General specifications 
 Isolation: 5000 Vrms 