3.3  RS-485 Cable Interface 
A typical RS-485 network is formed by two wires.    A9240-A-004-485 RFID reader’s 
RS-485 interface uses RJ-45 type connector.      Proper wire connections should be made 
before inserting the cable into the RS-45 connector. It is recommended that signal wire be 
twisted with ground wire as shown in the diagram below to minimize noise and interference. 
Pin 8 (B) of the RJ-45 connector should be used for the non-inverting RS-485 data signal.   
Pin 2 (O) of the RJ-45 connector should be used for the inverting RS-485 data signal.     
Ground should be connected to Pin 7 (BW) and Pin 1 (OW) of the RJ-45 connector. 