www.amico.com 13
Installation Precautions
Tampering with gas specic connections shall be prohibited. Do not alter, remove or modify gas specic connections.
Keep all manifold parts, tools and work surfaces free of oil, grease and dirt. These and other ammable materials may
ignite when exposed to high pressure oxygen or nitrous oxide.
Do not use chemicals, lubricants or sealants unless specied in these instructions
Before connecting the Liquid tank / Dewar to the manifold, ensure the tank valve is free of dirt and debris
After connecting the tank to manifold, open the tank valve S-L-O-W-L-Y to allow heat of compression to dissipate
Do not use ame or “sni tests for leaks
Do not apply heat to any part of the manifold system
Always ensure Liquid tanks / Dewars are secure and on level oor
Do not repeatedly bend, sharply bend, or twist pigtails as damage to tubing may occur
After the manifold wall bracket has been mounted, at least two people should lift and hang the manifold cabinet, one
should not do this alone
Do not put the manifold into operation until veried by a qualied person as per NFPA 99 or other local standards