User's Manual

Date:2008/09/10
Version: 1.401
Status: Released
9/11 ACM8060 Product Data Sheet V1.4©Copyright 2008, Amod Technology
Table 0-9 Operation current requirement
Operation mode Min TYP Max Unit
Standby mode - - 3.8 mA
Talking mode - 250 - mA
GPRS data - 350(GPRS4+1) - mA
Power off mode - 100 µA
The peak current of ACM8060 is 2A.
Power On/Off the module
1.10. General Description
The power on and off procedures are described in this chapter.
1.11. Power On
When the module is supplied with over 3.4V power and PWON signal is low (300ms),
ACM8060 will be powered on.
1.12. Power Off
To power off ACM8060, the external CPU needs to pull low PWON for 2 to 3
seconds to power off the board.