User Guide

Ampex 1308904-X4 Preliminary Draft A-15
ACL Application Programmer’s Guide CHS Failure, Error, and Warning Codes
553d (229h) Z-motor drive failed on a get
554d (22Ah) Y-servo did not lock on a get
555d 22B(h) Z-out lock failed on a get
556d (22Ch) Z-in lock failed on a get
557d 22D(h) Z-out move not started for get
559d (22Fh) Z-out motion stopped on a get
560d (230h) Z-in motion stopped on a get
561d (231h) Cart stuck in I/O port for get
562d (232h) Cart stuck in drive for a get
563d (233h) Cart stuck in a bin for a get
564d (234h) Cart rescue failed for a get
565d (235h) Cart out of reach, no rescue
GENERAL PROCEDURE FAULTS (8XX)
601d (259h) State controller timed out
602d (25Ah) Master sequencer timed out
RESET PROCEDURE FAULTS (8XX)
604d (25Ch) Safety lock is on
605d (25Dh) X-axis motor drive assembly (MDA) cannot be enabled
606d (25Eh) Y-axis MDA cannot be enabled
607d (25Fh) Z-axis MDA cannot be enabled
608d (260h) X-axis Servo cannot be enabled
609d (261h) Y-axis Servo cannot be enabled
610d 262(h) Z-axis Servo cannot be enabled
611d (263h) X-axis tachometer counter out of range
612d (264h) Y-axis tachometer counter out of range
613d (265h) Z-axis tachometer counter out of range
614d (266h) Cannot purge cartridge from CHS
615d (267h) Cannot clear CHS hook
616d (268h) Z-axis hook cannot be moved
Table A-5. CHS Failure, Error, and Warning Codes (Continued)
CHS Code Description