User Guide
Ampex 1308911-02 6-23
DD-2 Utilities Manual Pages dd2_gettrace_drive
6.8 dd2_gettrace_drive 
NAME 
dd2_gettrace_drive - get a firmware trace log from the tape drive. 
SYNOPSIS 
dd2_gettrace_drive -stdout <output_spec> [ -f <device_special_file> ] [ -n ] 
 dd2_gettrace_drive -help [ help_type ] 
DESCRIPTION 
dd2_gettrace_drive gets a tape drive firmware trace log. The information in the log is 
intended to aid service personnel in diagnosing and correcting problems.
dd2_gettrace_drive is available to all users.
OPTIONS
-f <
device_special_file
>
Specifies the device special file to use for the operation (see Appendix B).
-n
Prevents a trailing newline from being appended to the output stream. If omitted, the output 
stream includes a trailing newline.
ARGUMENTS
-help [ 
help_type
 ]
Displays help on stderr and invalidates all other options, cancelling any other actions. Valid 
keywords for the optional help_type specification are: stdout, revision, and v_revision.
-stdout <
output_spec>
Specifies the output fields written to stdout. You must provide a -stdout <output_spec> 
argument except when using the -help argument.
The -stdout <output_spec> argument supports the following keywords: 
%pcf  Specifies the process control firmware trace log. 