User Guide
Ampex 1308911-02 C-5
Result Codes and Machine Status Introduction
37 25h Reserved for internal use.
38 26h Reserved for internal use.
39 27h Non-recording Detected - A write or format operation has failed due to 
detection that older data or no data was read while writing.
40 28h Completed - A queued Physical Block command has been successfully 
executed, but the MSR has entered a suspended state due to the 
failure of a previous command in the queue. This Result Code may 
occur due to latency in the validation of Physical Block commands with 
respect to the execution of following commands. Note that the MSR 
advances its Implicit (Read/Write) Position after executing both 
successful and failed Physical Block commands.
41 29h Missed Pre-position Target - The first derived ADFN reported by the 
transport after achieving roll speed lock was already beyond the read/
write target, or the derived ADFN at the target did not match the helical 
SubArea ADFN, or helical tracks were not properly phase locked to the 
Double Frame reference just before the write target.
42 2Ah Beyond Search Target - The first derived ADFN reported by the 
transport (Absolute mode) or seen in the SubArea (Logical modes) was 
already beyond the search target.
43 2Bh Search Target Found in Wrong Partition - A Logical mode position 
command has terminated with SubArea data indicating the address 
found is not in the target partition. This could occur if, for example, an 
incorrect ADFN was supplied in mixed-mode positioning.
44 2Ch Unsupported Configuration For This Operation - An operation was 
attempted which is not supported for the current Configuration 
Parameter settings; this may be either a firmware or hardware 
limitation.
45 2Dh Environmental Fault - A problem has been detected involving a 
voltage, temperature or other environmental condition, such that the 
command being executed cannot complete successfully.
46 2Eh Unable to Rewrite - A failure has been detected in read-after-write 
verification after the last rewrite decision point, e.g., a C3 or Physical 
Block checksum error.
47-254 Reserved
255 FFh Reserved for debugging.
Table C-2. MSR Result Code Definitions (Continued)
Code 
Hex Meaning