User Guide

C-10 Ampex 1308911-02
Model No.
Running Head
Introduction Result Codes and Machine Status
24 3 Panic Cartridge Unload - The transport detected a fatal error and
has elevated the cartridge in order to prevent accidental recording
or damage.
24 2 Environmental Limit - An MSR-Electronics or -Transport power
supply, temperature or air supply sensor has detected an out-of-
range condition.
24 1 Transport Servo Error - The transport has reported an error in
scanner, capstan, reel or tracking servos.
24 0 Transport Engagement Error - The transport has reported an
error in the cartridge handling and tape engagement servo
subsystem.
*
HTKN = Helical Track Number
*
MSI = Mass Storage Interface
*
MSR = Mass Storage Recorder
*
PCF = Process Control Function
Table C-5. Bitmasks for Valid Member of dst_result_st
Defined Bitmasks
DST_R_CODE_VALID 0x00000001
DST_MSR_CODE_VALID 0x00000002
DST_MSI_CODE_VALID 0x00000004
DST_MSR_STAT_VALID 0x00000008
DST_R_CLASS_VALID 0x00000010
DST_SEVERITY_VALID 0x00000020
Table C-6. Rclass Member of dst_result_st
Defines Description
DstClsNotReady Not ready
DstClsMediumErr Medium error
DstClsHardwareErr Hardware error
DstClsIllegalReq Illegal request
DstClsCmdTransfer Command transfer
DstClsOtherErr Everything else
DstClsNoErr Absolutely no error
Table C-4. Machine Status Definitions (Continued)
Byte
Bit Description