User Guide

D-6 Ampex 1308911-02
Model No.
Running Head
Latched/Continuous Status Field MSR Diagnostic Status Information
93 3 C1 ECC Encoder Output (Formatter) Mux Port B Parity Error, High
Byte
93 2 C1 ECC Encoder Output (Formatter) Mux Port B Parity Error, Low
Byte
93 1 C2 ECC Encoder Input Mux Port A Parity Error, High Byte
93 0 C2 ECC Encoder Input Mux Port A Parity Error, Low Byte
94-97 31-0 Reserved
98-101 31-0 Reserved
102 3 C2 Encoder ECC Control ASIC Hidden Register Write Error
102 2 C2 Decoder ECC Control ASIC Hidden Register Write Error
102 1 C1 Encoder ECC Control ASIC Hidden Register Write Error
102 0 C1 Decoder ECC Control ASIC Hidden Register Write Error
103 7 Track Sequence Error in PB According to Subarea
103 6 No New Recording Found on H-tracks According to SubArea,
Head 1 - Set if a time stamp miscompare is found on a track read by
head 1.
103 5 No New Recording Found on H-tracks According to SubArea,
Head 2 - Set if a time stamp miscompare is found on a track read by
head 2.
103 4 No New Recording Found on H-tracks According to SubArea,
Head 3 - Set if a time stamp miscompare is found on a track read by
head 3.
103 3 No New Recording Found on H-tracks According to SubArea,
Head 4 - Set if a time stamp miscompare is found on a track read by
head 4.
103 2 SubArea Checksum Error with No SubArea C2 Generated Erasure,
Channel 1
103 1 SubArea Checksum Error with No SubArea C2 Generated Erasure,
Channel 2
104 7-0 Reserved
105-123 151-0 Reserved
124 7-0 Reserved
125 7-0 Reserved
Unit Error Summary Flags — Electronics
Table D-2. Latched/Continuous Status Parameters (Continued)
Byte Bit Description