Datasheet

27
Technical
Information
Termination methods
Screw connection
Screw clamps are designed acc. to EN 60999-1 / VDE 609-1.
Chart 1 below shows the screw size depending
on wire size and the required clamping and testing
torque..
Chart 1
Diagram 1 below shows the range of tensile strength for a screw
connection with a clamp screw M3, fastened with a torque of 50
Ncm, depending on the wire size.
Diagram 1
Wire size (mm
2
)
max.4
Screw size
M3
Test torque(Ncm)
50
Tensile strength
Wire gauge
This comparison chart allows a cross reference between American
Wire Gauge (AWG) and metric wire sizes (mm
2
).
Chart 2
It has to be noted that wires of the same AWG number but with
different composition have slightly different mm
2
.
AWG Wire Composition
Wire diameter
30 1 x 0.25 0.25 mm 0.05 mm
2
7 x 0.10 0.36 mm 0.06 mm
2
28 1 x 0.32 0.32 mm 0.08 mm
2
7 x 0.13 0.38 mm 0.09 mm
2
26 1 x 0.40 0.40 mm 0.13 mm
2
7 x 0.16 0.48 mm 0.14 mm
2
19 x 0.10 0.51 mm 0.15 mm
2
24 1 x 0.51 0.51 mm 0.21 mm
2
7 x 0.20 0.61 mm 0.23 mm
2
19 x 0.13 0.64 mm 0.24 mm
2
22 1 x 0.64 0.64 mm 0.33 mm
2
7 x 0.25 0.76 mm 0.36 mm
2
19 x 0.16 0.81 mm 0.38 mm
2
20 1 x 0.81 0.81 mm 0.52 mm
2
7 x 0.32 0.97 mm 0.56 mm
2
19 x 0.20 1.02 mm 0.62 mm
2
18 1 x 1.02 1.02 mm 0.79 mm
2
19 x 0.25 1.27 mm 0.96 mm
2
16 19 x 0.29 1.44 mm 1.23 mm
2
14 19 x 0.36 1.80 mm 1.95 mm
2
12 19 x 0.46 2.29 mm 3.09 mm
2
10 37 x 0.40 3.10 mm 4.60 mm
2
8 133 x 0.29 4.0 mm 8.80 mm
2
6 133 x 0.36 5.5 mm 13.5 mm
2
Chart 3
Composition and Dimensions of Copper Wires
Wire Size Wire Composition Wire diameter
0.09 mm
2
12 x 0.10 0.48 mm
0.14 mm
2
18 x 0.10 0.50 mm
0.25 mm
2
14 x 0.15 0.70 mm
0.34 mm
2
7 x 0.25 0.78 mm
0.5 mm
2
16 x 0.20 1.0 mm
0.75 mm
2
24 x 0.20 1.2 mm
1.0 mm
2
32 x 0.20 1.4 mm
1.5 mm
2
30 x 0.25 1.6 mm
2.5 mm
2
35 x 0.30 2.2 mm
4.0 mm
2
56 x 0.30 2.8 mm
6.0 mm
2
19 x 0.64 3.4 mm
10 mm
2
19 x 0.80 4.3 mm
Wire size