Standard Technical dataGeneral Characteristics
Number of contacts 8 + PE
Shell size 1
14 + PE
17 + PE
12 + 3 + PE
400 V
3
III
II
6000 V
12 A
6 A
10
8
Ω
5 mΩ
40 / 125 / 56
-40°C ... +125°C
IP 65
500 mating cycles
Polyamide 6.6
Polyamide 6.6
silver plated / gold plated
crimp
Neoprene
VO
bayonet
0,14 - 2,5 mm
2
/
26 - 14
0,09 - 2,5 mm
2
/
28 - 14
0,09 - 1,0 mm
2
/
28 - 18
25 N 30 N
22 N
25
N
3 x 12 A, 12 x 6 A
3 x 16 A, 11 x 6 A
3000 V
3000 V
3 x 4000 V, 12 x 800 V
II II
II
III
III
III
3
3
3
100 V 100 V
3 x 320 V, 12 x 24 V
Electrical Characteristics
Rated voltage
Pollution degree
Installation (overvoltage) category
Material group
Rated impulse withstand voltage
Current carrying capacity
Insulation resistance
Contact resistance
Climatic Characteristics
Climatic category
Operating temperature
Mechanical Characteristics
Degree
of protection
DIN EN 60512-5-2,
test 5b
DIN EN 60512-3-1,
test 3a
DIN EN 60512-2-1,
test 2a
DIN EN 60664-1
1)
DIN EN 60664-1
1)
DIN EN 60664-1
1)
DIN EN 60664-1
1)
DIN EN 60664-1
1)
DIN EN 60068-1
DIN EN 60529
Insertion and withdrawal force
Mechanical operation
Materials
Housing material
Dielectric material
Gasket material
Contact plating
Other Characteristics
Termination technique
Wire gauge / AWG
Flammability
Locking system
DIN EN 60512-13-2,
test 13b
IEC 60512,
test 9a
C 16-3
Technical data
Shell size 1
The stated technical values refer to the use as connector.
If these components are used as plug and socket device a reduced current carrying capacity has to be considered.
UL 94
1)
DIN 60664-1
^
= VDE 0110-1
^
= DIN EN 60664-1
UL 1977, CSA 22.2
400 V
3 x 250 V, 11 x 250 V
250 V
3 x 250 V, 12 x 24 V
UL 1977, CSA 22.2
10 A
3 x 12 A, 11 x 4 A
5 A
3 x 10 A, 12 x 5 A
0,09 - 2,5
mm
2
/
28- 14