Remarks / Safety Classification
1. General Remarks
These connectors are designed and produced in conformity with the
low voltage directive (73/23/EWG) respectively
GerÀtesicherheitsgesetz (German law) and are especially in
accordance with the standards DIN EN 61984 / IEC 61984 (VDE
0627); IEC 60664-1 (VDE 0110-1) and IEC 60529.
The connectors may be used only within the technical ratings.
All technical data refer to mated connectors under live conditions.
The safety of the connector system depends on the correct selection
of products, proper assembly of the connector device and a precise
fit of the connectors
2. Application Remarks
Connectors with / without breaking capacity must be used according to
specified technical ratings.
The technical data represents the initial value of mated parts under
predetermined conditions and length of time.These values could change
with different test parameters or product requirements.
The connectors of the series are designed for the areas of
application including the construction and installation of controlling
and electrical devices.
The product has been tested for the intended purposes only. If the
connection is used other than originally intended, or in another
manner that we have not previously tested, the consumer assumes full
responsibility.
All rated data for the connectors listed in this catalogue are based on
overvoltage
category III and pollution degree 3 for electronic applications if
not stated differently. Connectors were completely mated according to their
respective safety locking mechanism. Selection and testing of connectors
with / without breaking capacity to meet specific product or industrial
requirements such as rated voltage and the related clearances and creepage
distances are the responsibility of the user.
3. Assembling Remarks
Protection against electrical shock of the termination of the
connectors shall be secured by correct mounting. Connectors of the
same or different series being mounted side by side may be protected
against incorrect mating by the use of coding options. Care must
be taken to ensure the parts are correctly mated and screws are
tightened with the proper torque.
4. Termination Remarks
Cable connectors are eff ectively secured when using the strain relief
(internal clamping ring). All cable properties or specifi cations must
becompatible with the connector design and materials.
Please make sure that the usability of the cable in conjunction with
the clamping ring is given.
Designated wire conductors must be terminated to the correct poles
in the connector.
Crimp contacts must be fully inserted into the plastic housing and
strain relief assured with a slight tug on the wire.
Wire should be stripped correctly according to printed specifi cations
to insure no electrical contact can be made between the conductors.
There should be no nicked or cut strains during the stripping action.